HP R-3A, R-2A, R-2 MD01, R-2 RDR manual Index

Page 87

RPC-SERIES OWNER’S MAP INDEX

INDEX

A

Adapter, 2, 5, 6, 8, 12, 16, 19, 20, 27, 28, 37 Adapters, 59

Applications Engineer, iii Asynchronous, 17 ATDT Commands, 31

C

Cable, 18

Cables, 59

Cabling, 15

Circuit Breaker, 2, 6, 14, 21, 29, 70 Communications Software, 2, 5, 8, 20, 27,

29, 31, 37 Computer Adapter, 17 Computer/Terminal Adapter, 16 Configuration, 3, 7, 10, 11, 19, 22, 32 Copyright, ii

Current Password, 23, 24, 33, 44

D

Default, 4, 7, 10, 23, 26, 32, 33, 47, 48, 49, 51, 52, 66, 67

diagnostic, 68

E

EIA-232 Port, 1, 5, 6, 8, 14, 15, 19, 20, 27,

28, 37, 64

Emulation, 3, 6, 7, 59

Ethernet Hub, 8

Ethernet Port, 8, 37

Exit, 47, 48, 55

External Modem, 6, 12, 15, 19, 27, 28, 37,

69

F

FCC Requirements, 62

FCC Rules, 62

FCC Statement, 62

G

Gateway, 47, 48, 49

I

Installation, 12

Interface, 62

Internal Modem, 1, 28

Internal Relays, 14

IP Address, 10, 37, 47, 48, 68

L

LED, 13, 20, 29, 39, 65, 68, 69

Local Access, 5, 27, 37

Local Operations, 38

Login, 8, 38, 44, 49

M

Modem, 1, 5, 6, 12, 15, 17, 19, 27, 28, 31, 37, 65, 69

Modem Adapter, 12

Modem Command Summary, 28, 66, 67 Modem Connections, 5, 28

Modular connectors, 18

N

Network Configuration, 10, 47, 48

O

Operations, 2, 6, 8, 20

P

Password, 3, 4, 7, 22, 24, 31, 32, 33, 34, 44, 45, 47, 49, 69, 71

Password Protection, 24, 34 Pin Signal Definition, 16

Power, 1, 5, 8, 13, 14, 20, 22, 28, 29, 31, 38, 39, 42, 55, 65, 68, 70

Power On/Off State, 14

Power Up Sequence, 14

80

Image 87
Contents BayTech Manual Publication #U140E125-03 July RPC-2 RDR RPC-3 RPC-3A RPC-5Page Page Page Page ADD User Delete User Change Password Vii Introduction to the Remote Power Control Switch RPC 115 VAC, 50/60 Hz, 15 Amp230 VAC, 50/60 Hz, 10 Amp RPC Series Quick Start RPC-2 and RPC-2A Quick StartOperation Or for the RPC-2A RPC Series Quick Start RPC-2 and RPC-2A RPC-2 RDR RPC-2 MD01 and RPC-2 RDR Quick StartOperation Change Password ConfigurationRemote access using RPC-3, RPC-3A and RPC-5 Quick StartNetwork port Deletion of the admin user is prohibited Outlet ControlManage Users List Change Password Default password is cr disabled8. Default is no outlets selected Change OutletReset Unit Unit StatusLogout Installation Preparing the Installation SiteUnpacking Power Power ON/OFF State Power UP SequenceCircuit Breaker RJ-45 Cables and Adapters CablingRPC RJ-45 control port uses the following signals Computer/Terminal Adapter Crossed 8-pin Modular Cable RPC-2 and RPC-2A Detailed Operation ConfigurationRPC’s main menu allows the user to Controlling Receptacles Detailed Operation and Configuration Select #1, Change Password, and press Enter New Password Key at the Enter Request prompt To return to the RPC prompt, press anyChange the current status. Default is From the configuration menu, select #3Enable/Disable Confirmation Switch, the RPC responds with the option toSerial Connection Local AccessUsing the EIA-232 RPC-2 MD01 and RPC-2 RDRRemote Access Using Modem Connections RPC’s main menu allows you to Responding Y for yes turns On Outlet If prompted, enter password. The following main menu appears Outlet RPC Config RPC Outlet Enter Request RPC-3 and RPC-3A and RPC-5 Port Connection Using EIA-232Remote Access Using NetworkOperation Detailed Operation and Configuration And/or password has been entered, the main If this is not an initial setup and usernameAnd/or password have been enabled, you Password. When a successful usernameResponding Y for yes turns On Outlet Observe the status of Outlet 3 has changedTo On in the status menu With the option to delete users If this is not an initial setup and optionalOutlet users have been added, they too will Show in the User Management Menu, alongDelete user Add UserDefault password is cr Enter new password = 8 characters To change outlet access, enter numbers of outlets. If Network port. From the RPC Main Menu Configuration can be performed byAdmin user only via the serial port or Select #3, Configuration. The followingDefault Subnet Mask is 0.0.0.0. If you fail Access Default Unit ID is RPC-3Outlet Operation Configuration Menu Disable Outlet Status Display? Y/N Unique set-up.Default outlet names are Name OutletsOutlet 1, Outlet 2, Outlet 3 . . . Outlet To return to the configuration menu, press any key Interface, logged user status, and outlet Status. In the event of problems withUnit status provides vital information about RPC unit system status, networkSystem Status Enter the number of the session to terminate RPC responds Changes Reset the unit to load new configurationStatus Technical Support Outlet Equipment SetupRPC Series Unit Model RPC Series Unit Serial Number Outlet OUTLET3Call BayTech to get a Return Authorization Number REPACKAGING, Shipping and Returning to the FactoryInstructions for Repackaging and Shipping FCC Requirements for the RPC-2 MD01 and RDR FCC Radio Frequency Interface StatementFCC Radio Frequency Interface Statement Appendix a SpecificationsSpecifications Modem Command Summary Appendix BRobotic Modems Rockwell Chip SET Modems Save modem’s configuration in non-volatile memoryDiagnostic LED Indications Appendix CIndication Interpretation RPC Troubleshooting Guide Problem Symptom Cause SolutionAppendix D Appendix D RPC Troubleshooting Guide Cont’ Appendix D RPC Troubleshooting Guide Cont’ RPC-2 Appendix E- DrawingsRPC-2A RPC-2 MD01 RPC-2 RDR RPC-3 RPC-3A RPC3/3A/5 Ethernet Board RPC-5 Index Shipping