RPC SERIES OWNER’S MANUAL INSTALLATION

________________________________________________________________________________

POWER

CAUTION: This unit is intended for indoor use only. Do not install near water or expose this unit to moisture. To prevent heat buildup, do not coil the power cord when in use. Do not use extension cords. Do not attempt to make any internal changes to the power source. Do not attempt to modify any portion or component of an RPC Series Unit unless specifically directed to. BayTech must perform any internal operations.

CAUTION: High-voltage surges and spikes can damage this equipment. To protect from such power surges and spikes, this unit must have a good earth ground. There is an earth ground connection next to the circuit breaker.

CAUTION: Before removing or replacing any cables or power cords, turn off main power switch located on the RPC Series Unit. Communication to the unit will be disrupted while power is off.

CAUTION: Do not exceed the AC current rating for the selected model. (See Appendix A “SPECIFICATIONS” for each RPC model).

CAUTION: Although the power switch is turned OFF, the unit is not totally isolated from the power supply. In order to be absolutely removed from the power supply, the power cord must be unplugged from the unit.

CAUTION: For PERMANENTLY CONNECTED EQUIPMENT, a readily accessible disconnect device shall be incorporated in the fixed wiring. For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and easily accessible.

Applying power illuminates a green LED on the front panel of the RPC. When the power switch is off, devices connected to the unit are not receiving power.

13

Image 20
Contents RPC-2 RDR RPC-3 RPC-3A RPC-5 BayTech Manual Publication #U140E125-03 JulyPage Page Page Page ADD User Delete User Change Password Vii 230 VAC, 50/60 Hz, 10 Amp Introduction to the Remote Power Control Switch RPC115 VAC, 50/60 Hz, 15 Amp Operation RPC Series Quick StartRPC-2 and RPC-2A Quick Start Or for the RPC-2A RPC Series Quick Start RPC-2 and RPC-2A RPC-2 MD01 and RPC-2 RDR Quick Start RPC-2 RDROperation Configuration Change PasswordNetwork port Remote access usingRPC-3, RPC-3A and RPC-5 Quick Start Manage Users Deletion of the admin user is prohibitedOutlet Control Change Password Default password is cr disabled 8. Default is no outlets selected Change Outlet ListLogout Reset UnitUnit Status Unpacking InstallationPreparing the Installation Site Power Circuit Breaker Power ON/OFF StatePower UP Sequence Cabling RJ-45 Cables and AdaptersRPC RJ-45 control port uses the following signals Computer/Terminal Adapter Crossed 8-pin Modular Cable Detailed Operation Configuration RPC-2 and RPC-2ARPC’s main menu allows the user to Controlling Receptacles Detailed Operation and Configuration Select #1, Change Password, and press Enter New Password To return to the RPC prompt, press any Key at the Enter Request promptFrom the configuration menu, select #3 Enable/Disable ConfirmationSwitch, the RPC responds with the option to Change the current status. Default isLocal Access Using the EIA-232RPC-2 MD01 and RPC-2 RDR Serial ConnectionRemote Access Using Modem Connections RPC’s main menu allows you to Responding Y for yes turns On Outlet If prompted, enter password. The following main menu appears Outlet RPC Config RPC Outlet Enter Request RPC-3 and RPC-3A and RPC-5 Using EIA-232 Remote AccessUsing Network Port ConnectionOperation Detailed Operation and Configuration If this is not an initial setup and username And/or password have been enabled, youPassword. When a successful username And/or password has been entered, the mainTo On in the status menu Responding Y for yes turns On OutletObserve the status of Outlet 3 has changed If this is not an initial setup and optional Outlet users have been added, they too willShow in the User Management Menu, along With the option to delete usersAdd User Delete userDefault password is cr Enter new password = 8 characters To change outlet access, enter numbers of outlets. If Configuration can be performed by Admin user only via the serial port orSelect #3, Configuration. The following Network port. From the RPC Main MenuDefault Subnet Mask is 0.0.0.0. If you fail Default Unit ID is RPC-3 AccessOutlet Operation Configuration Menu Disable Outlet Status Display? Y/N Outlet 1, Outlet 2, Outlet 3 . . . Outlet Unique set-up.Default outlet names areName Outlets To return to the configuration menu, press any key Status. In the event of problems with Unit status provides vital information aboutRPC unit system status, network Interface, logged user status, and outletSystem Status Enter the number of the session to terminate RPC responds Reset the unit to load new configuration ChangesStatus Technical Support Equipment Setup RPC Series Unit Model RPC Series Unit Serial NumberOutlet OUTLET3 OutletInstructions for Repackaging and Shipping Call BayTech to get a Return Authorization NumberREPACKAGING, Shipping and Returning to the Factory FCC Radio Frequency Interface Statement FCC Requirements for the RPC-2 MD01 and RDRFCC Radio Frequency Interface Statement Specifications Appendix aSpecifications Robotic Modems Modem Command SummaryAppendix B Save modem’s configuration in non-volatile memory Rockwell Chip SET ModemsIndication Interpretation Diagnostic LED IndicationsAppendix C Appendix D RPC Troubleshooting GuideProblem Symptom Cause Solution Appendix D RPC Troubleshooting Guide Cont’ Appendix D RPC Troubleshooting Guide Cont’ Appendix E- Drawings RPC-2RPC-2A RPC-2 MD01 RPC-2 RDR RPC-3 RPC-3A RPC3/3A/5 Ethernet Board RPC-5 Index Shipping