HP R-3A, R-2A, R-2 MD01, R-2 RDR manual Responding Y for yes turns On Outlet

Page 37

RPC SERIES OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

________________________________________________________________________________

If the status menu fails to appear, ensure the correct cables and adapters are being used and that they are connected properly. Also, verify the serial communication parameters are correctly configured.

Controlling Receptacles

To set or change the status of receptacles,

 

enter one of the following commands: ON

 

n, OFF n, REBOOT n, where “n” is the

 

outlet number you want to command.

 

Entering an outlet number of “0” sends the

 

command to all outlets.

Example:

To turn “On” Outlet 3, type ON 3 from the

 

RPC prompt (RPC >). The RPC responds:

 

Turn On Outlet 3 (Y/N)?

 

Responding “Y” for yes turns “On” Outlet 3.

 

Observe that the status of Outlet 3 has

 

changed to On in the status menu:

RPC-2 Series

(c)1997 by BayTech

F2.07

Circuit Breaker : On

1) . . . OUTLET 1

: Off

2) . . . OUTLET 2

: Off

3) . . . OUTLET 3

: On

4) . . . OUTLET 4

: Off

5) . . . OUTLET 5

: Off

6) . . . OUTLET 6

: Off

RPC >

 

Likewise, typing ON 0 at the RPC > prompt and responding “Y” for yes, turns “On” all outlets. Typing OFF n at the RPC > prompt turns off corresponding outlet(s).

30

Image 37
Contents BayTech Manual Publication #U140E125-03 July RPC-2 RDR RPC-3 RPC-3A RPC-5Page Page Page Page ADD User Delete User Change Password Vii 115 VAC, 50/60 Hz, 15 Amp Introduction to the Remote Power Control Switch RPC230 VAC, 50/60 Hz, 10 Amp RPC-2 and RPC-2A Quick Start RPC Series Quick StartOperation Or for the RPC-2A RPC Series Quick Start RPC-2 and RPC-2A RPC-2 RDR RPC-2 MD01 and RPC-2 RDR Quick StartOperation Change Password ConfigurationRPC-3, RPC-3A and RPC-5 Quick Start Remote access usingNetwork port Outlet Control Deletion of the admin user is prohibitedManage Users 8. Default is no outlets selected Change Password Default password is cr disabledChange Outlet ListUnit Status Reset UnitLogout Preparing the Installation Site InstallationUnpacking Power Power UP Sequence Power ON/OFF StateCircuit Breaker RJ-45 Cables and Adapters CablingRPC RJ-45 control port uses the following signals Computer/Terminal Adapter Crossed 8-pin Modular Cable RPC-2 and RPC-2A Detailed Operation ConfigurationRPC’s main menu allows the user to Controlling Receptacles Detailed Operation and Configuration Select #1, Change Password, and press Enter New Password Key at the Enter Request prompt To return to the RPC prompt, press anyEnable/Disable Confirmation From the configuration menu, select #3Switch, the RPC responds with the option to Change the current status. Default isUsing the EIA-232 Local AccessRPC-2 MD01 and RPC-2 RDR Serial ConnectionRemote Access Using Modem Connections RPC’s main menu allows you to Responding Y for yes turns On Outlet If prompted, enter password. The following main menu appears Outlet RPC Config RPC Outlet Enter Request RPC-3 and RPC-3A and RPC-5 Remote Access Using EIA-232Using Network Port ConnectionOperation Detailed Operation and Configuration And/or password have been enabled, you If this is not an initial setup and usernamePassword. When a successful username And/or password has been entered, the mainObserve the status of Outlet 3 has changed Responding Y for yes turns On OutletTo On in the status menu Outlet users have been added, they too will If this is not an initial setup and optionalShow in the User Management Menu, along With the option to delete usersDelete user Add UserDefault password is cr Enter new password = 8 characters To change outlet access, enter numbers of outlets. If Admin user only via the serial port or Configuration can be performed bySelect #3, Configuration. The following Network port. From the RPC Main MenuDefault Subnet Mask is 0.0.0.0. If you fail Access Default Unit ID is RPC-3Outlet Operation Configuration Menu Disable Outlet Status Display? Y/N Name Outlets Unique set-up.Default outlet names areOutlet 1, Outlet 2, Outlet 3 . . . Outlet To return to the configuration menu, press any key Unit status provides vital information about Status. In the event of problems withRPC unit system status, network Interface, logged user status, and outletSystem Status Enter the number of the session to terminate RPC responds Changes Reset the unit to load new configurationStatus Technical Support RPC Series Unit Model RPC Series Unit Serial Number Equipment SetupOutlet OUTLET3 OutletREPACKAGING, Shipping and Returning to the Factory Call BayTech to get a Return Authorization NumberInstructions for Repackaging and Shipping FCC Requirements for the RPC-2 MD01 and RDR FCC Radio Frequency Interface StatementFCC Radio Frequency Interface Statement Appendix a SpecificationsSpecifications Appendix B Modem Command SummaryRobotic Modems Rockwell Chip SET Modems Save modem’s configuration in non-volatile memoryAppendix C Diagnostic LED IndicationsIndication Interpretation Problem Symptom Cause Solution RPC Troubleshooting GuideAppendix D Appendix D RPC Troubleshooting Guide Cont’ Appendix D RPC Troubleshooting Guide Cont’ RPC-2 Appendix E- DrawingsRPC-2A RPC-2 MD01 RPC-2 RDR RPC-3 RPC-3A RPC3/3A/5 Ethernet Board RPC-5 Index Shipping