Paradyne 3165-A2, 3164-A2, 3160-A3, 3161-B3 manual Changing Configuration Options

Models: 3160-A3 3165-A2 3161-B3 3164-A2

1 298
Download 298 pages 18.84 Kb
Page 48
Image 48

3. Operation

If you chose a port, the Port n LEDs screen lists the LED signals, two at a time, on the second line. A vertical bar at the left of the LED name indicates the condition is ON, while an underscore indicates the condition is Off.

Port n LEDs:

_DTR _TXD

F1 F2 F3

5. Use the and keys to scroll LED names onto the screen.

Changing Configuration Options

The DSU/CSU is an intelligent device that displays only valid options for the current configuration. Therefore, you are only presented with menu choices that are consistent with the current configuration and operational state of the DSU/CSU; invalid combinations of configuration options do not appear. For example, menus displayed for the Model 3160 (2 ports) and the Model 3164 (4 ports) differ due to the number of ports available. Also, if the DTE Drop/Insert (DSX-1) interface selection is disabled, many of the menu choices do not appear. Be aware that although all options are shown in this guide, what you see on your DSU/CSU varies with your configuration.

The DSU/CSU offers configuration options located in the following memory areas:

Active (Activ) – This is the configuration option set currently active for the DSU/CSU. Before a configuration option set becomes active for the DSU/CSU, you must save the set to the Active area. When the DSU/CSU is shipped from the factory, the Active configuration option set is identical to the Factory set. This area can be written to and controls the current operation of the device.

Customer 1 (Cust1) – This is the first of two sets of customer-defined configuration options. This area can be written to.

Customer 2 (Cust2) – This is the second of two sets of customer-defined

Tconfiguration options. This area can be written to.

Factory 1 (Fact1) – This is a set of configuration options preset at the factory. This set is determined by what is considered to be the most common

Tconfiguration used in the DSU/CSU market. Factory 1 options are read-only.

Factory 2 (Fact2) – This is a set of configuration options preset at the factory. This set is determined by what is considered to be the second most common configuration used in the DSU/CSU market. Factory 2 options are read-only.

3-14

February 2001

3160-A2-GB21-90

Page 48
Image 48
Paradyne 3165-A2, 3164-A2, 3160-A3, 3161-B3 manual Changing Configuration Options