Configuration Worksheets for the Asynchronous Terminal Interface

This section contains one set of blank worksheets to be used when configuring your DSU/CSU using the async terminal interface. In the tables, default settings for Default Factory 1 are indicated by bold type. It is recommended that you copy these blank worksheets before using them.

Network Interface

 

 

Options

Front Panel Equivalent

Value (Default in Bold)

 

 

 

Line Framing Format

NET Framing

D4, ESF

 

 

 

Line Coding Format

NET Coding

AMI, B8ZS

 

 

 

Line Build Out (LBO)

LBO

0.0, –7.5, –15, –22.5

 

 

 

Management Link

Mgmt Link

Enable, Disable

 

 

 

Bit Stuffing

BitStuff

62411, Part68, Disable

 

 

 

Network Initiated LLB

NET LLB

Enable, Disable

 

 

 

Network Initiated PLB

NET PLB

Enable, Disable

 

 

 

ANSI Performance Report

ANSI PRM

Enable, Disable

Messages

 

 

 

 

 

Circuit Identifier

Circuit Ident

Text Field, Clear

 

 

 

 

 

 

DTE Interface Options

Front Panel Equivalent

Value (Default in Bold)

 

 

 

Interface Status

DTE Port

Enable, Disable

 

 

 

Line Framing Format

DTE Framing

D4, ESF

 

 

 

Line Coding Format

DTE Coding

AMI, B8ZS

 

 

 

Line Equalization

Equal

0133, 133–266, 266–399,

 

 

399–533, 533–655

 

 

 

DTE LB on External

Extrn DLB

Enable, Disable

Contact

 

 

 

 

 

Send All Ones on DTE

Send Ones

Enable, Disable

Failure

 

 

 

 

 

3160-A2-GB21-90