4. Maintenance

Table 4-3. Performance Registers (1 of 2)

Register

Interval Description

Totals Description

 

 

 

Event

ESF error events counter. An error

N/A

 

event is an ESF frame with either a

 

 

Cyclic Redundancy Check (CRC)

 

 

error or an Out Of Frame (OOF)

 

 

event. The maximum count is

 

 

65,535. This register is only reset

 

 

as a result of a reset command from

 

 

the network. This register is valid for

 

 

the current interval only.

 

 

 

 

CurTimer

Current interval timer. This register

N/A

 

records the number of seconds in

 

 

the current 15-minute interval. The

 

 

maximum is 900 seconds. This

 

 

register is valid for the current

 

 

interval only.

 

 

 

 

VldIntvl

N/A

Valid interval total. Records the

 

 

number of valid 15-minute intervals

 

 

in the previous x hours, where x is

 

 

24 hours for aggregate performance

 

 

and 8 hours for port performance.

 

 

This register is not valid for the

 

 

current interval.

 

 

 

ES

The number of errored seconds for

The total number of errored seconds

 

the current interval. An errored

for the previous x hours, where x is

 

second is any second with one or

24 hours for aggregate performance

 

more ESF error events. The

and 8 hours for port performance.

 

maximum is 900 seconds.

 

 

 

 

UAS

The number of unavailable seconds

The total number of unavailable

 

for the current interval. An

seconds for the previous x hours,

 

unavailable second is any one

where x is 24 hours for aggregate

 

second interval when service is

performance and 8 hours for port

 

unavailable. (Detection occurs with

performance.

 

10 consecutive unavailable

 

 

seconds.) The maximum is

 

 

900 seconds.

 

 

 

 

SES

The number of severely errored

The total number of severely errored

 

seconds for the current interval. A

seconds for the previous x hours,

 

severely errored second is any

where x is 24 hours for aggregate

 

second with 320 or more CRC

performance and 8 hours for port

 

errors, or any second with one or

performance.

 

more OOF events. The maximum is

 

 

900 seconds.

 

 

 

 

BES

The number of bursty errored

The total number of bursty errored

 

seconds for the current interval. A

seconds for the previous x hours,

 

bursty errored second is any

where x is 24 hours for aggregate

 

second with more than one, but less

performance and 8 hours for port

 

than 320, CRC errors. The

performance.

 

maximum is 900 seconds.

 

 

 

 

3160-A2-GB21-90

February 2001

4-9

Page 111
Image 111
Paradyne 3161-B3, 3165-A2, 3164-A2, 3160-A3 manual Event, CurTimer, VldIntvl