3. Operation

5. Select Gen.

Edit:

NET Chan Gen

F1 F2 F3

6.Press F1 (Next) to display the next configuration option (Clock Src).

7.Select the master clock source. For external, press the key until the Ext selection appears on the screen.

8.Select Ext (external timing).

Clock Src:Ext

Prt1 Int Ext

F1 F2 F3

9.Select the appropriate external clock rate by pressing the corresponding Function key. This step is mandatory if you have chosen external clocking.

Clock Rate:1544

Next 2048 1544

F1 F2 F3

Establishing Access Security on a Port

Although the password feature is available, it is not required as a factory default. If used, it ensures access security before device control is passed to a device connected to a port. The password configuration option can be individually set for the COM or MODEM port, or both if security is needed on both port types. The default is None. The password itself is set separately (refer to the following section, Setting a Password on page 3-49).

Procedure

To establish access security on a port:

1.From the top-level menu screen, select Cnfig.

2.Select the configuration option set to be copied into the Edit area by using the appropriate Function key. Use the scroll keys, if necessary.

3.Select Edit.

4.From the Edit screen, press the key until the User selection appears on the screen.

3-48

February 2001

3160-A2-GB21-90

Page 82