4. Maintenance

Device Health and Status

Use the Device Health and Status branch to view the current health and status messages for the DSU/CSU. Table 4-2, Device Health and Status Messages, lists these messages in priority order.

Procedure

To display device health and status:

1.From the top-level menu screen, select Stat.

2.From the Status screen, select DevHS.

Status:

DevHS STest Perf

F1 F2 F3

Alarm/status messages appear on Line 2 of the LCD in priority order (highest to lowest). The DSU/CSU is polled for current status every ten seconds. If the status has changed from the last poll, the Health and Status screen is updated and the highest priority message is displayed.

3.Use the scroll keys, if necessary, to scroll additional device health and status messages onto the LCD.

Device H/S:

OOF at DTE

F1 F2 F3

The Auto Device Health and Status screen appears when there is no activity (no keys pressed) on the active physical interface for five minutes. Only the highest priority message appears on Line 2 of the LCD.

Auto Dev H/S

OOF at DTE

F1 F2 F3

3160-A2-GB21-90

February 2001

4-3