Paradyne 3160-A3, 3165-A2, 3164-A2, 3161-B3 manual Device Health and Status Messages 1 Description

Models: 3160-A3 3165-A2 3161-B3 3164-A2

1 298
Download 298 pages 18.84 Kb
Page 106
Image 106

4. Maintenance

Table 4-2. Device Health and Status Messages (1 of 2)

Message

Description

 

 

LOS at Net

A Loss Of Signal condition (175 consecutive zeros) has been

 

detected on the network interface. The condition is cleared when the

 

density of ones to zeros received is 12.5%.

 

 

LOS at DTE

A Loss Of Signal condition (175 consecutive zeros) has been

 

detected on the DTE Drop/Insert (DSX-1) interface. The condition is

 

cleared when the density of ones to zeros received is 12.5%.

 

 

OOF at Net

An Out Of Frame condition (2 out of 4 frame synchronization bits in

 

error) has been detected on the network interface. The condition is

 

cleared when a reframe occurs.

 

 

OOF at DTE

An Out Of Frame condition has been detected on the DTE

 

Drop/Insert (DSX-1) interface. The condition is cleared when a

 

reframe occurs.

 

 

AIS at Net

An Alarm Indication Signal (unframed all ones signal) is being

 

received by the network interface.

 

 

AIS at DTE

An Alarm Indication Signal is being received by the DTE Drop/Insert

 

(DSX-1) interface.

 

 

EER at Net

An Excessive Error Rate condition has been detected on the

 

network interface (the bit error rate has exceeded the configured

 

threshold for ESF framing). The condition is cleared when the error

 

rate falls below the threshold value.

 

 

Yellow at Net

A Yellow Alarm signal is being received by the network interface.

 

 

Yellow at DTE

A Yellow Alarm signal is being received by the DTE Drop/Insert

 

(DSX-1) interface.

 

 

OOF at Prtn

An Out Of Frame condition has been detected on data port Prtn

 

(where n is the port number). This condition only occurs if the

 

synchronous data port’s Embedded Data Link (EDL) is enabled (only

 

available for 2-port and 4-port DSU/CSUs).

 

 

EER at Prtn

The error rate of the received signal has exceeded the configured

 

threshold for data port Prtn (where n is the port number). This

 

condition only occurs if the synchronous data port’s Embedded Data

 

Link (EDL) is enabled (only available for 2-port and 4-port

 

DSU/CSUs). The condition is cleared when the error rate falls below

 

the synchronous data port’s configured threshold value.

 

 

PORT IP Down

The IP management link is in a down state for PORT (where PORT

 

is COM, MODEM, or AUX). This condition occurs if the PORT is

 

configured for Mgmt, and communication between the management

 

system and the DSU/CSU is not currently possible for this port. For

 

the AUX port, this condition is detected only when a device reset or

 

power-up occurs.

 

 

Selftest failed

A failure was detected during the power-on self-test. Select STest (in

 

the Stat branch) to display more information about the failure.

 

 

DevFail xxxxxxxx

An internal error has been detected by the operating software. An

 

8-digit code appears for use by service personnel. The condition is

 

cleared by resetting the device.

 

 

Download failed

A download attempt was interrupted and failed to complete. The

 

condition is cleared by resetting the device.

 

 

4-4

February 2001

3160-A2-GB21-90

Page 106
Image 106
Paradyne 3160-A3, 3165-A2, 3164-A2, 3161-B3 manual Device Health and Status Messages 1 Description