4. Maintenance

5.The following screens alternately appear on the LCD until you press a Function key to return to the Lamp Test screen. In addition, all LEDs blink.

❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚

❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚ ❚

F1 F2 F3

0123456789 : ; < = > ?

@ABCDEFGHIJKLMNO

F1 F2 F3

6.When you are satisfied that all LEDs are lighting and the LCD is functioning properly, abort the Lamp test from the Lamp Test screen. If there is no activity on the DSU/CSU front panel for five minutes, the Device Health and Status screen appears automatically. However, the Lamp test remains active until it is aborted.

Aborting a Lamp Test

Procedure

To abort the Lamp test:

1.Display the Lamp Test screen. To do this when the LCD is alternating the Lamp test screens, press any Function key. Otherwise, follow Steps 1 through 3 for starting a Lamp test.

Lamp Test:

Abort Start

F1 F2 F3

2. From the Lamp Test screen, select Abort.

Lamp Test:

Abort Start

F1 F2 F3

4-36

February 2001

3160-A2-GB21-90

Page 138
Image 138
Paradyne 3160-A3, 3165-A2, 3164-A2, 3161-B3 manual Aborting a Lamp Test