Paradyne 3164-A2, 3165-A2, 3160-A3, 3161-B3 manual Sending Test Patterns

Models: 3160-A3 3165-A2 3161-B3 3164-A2

1 298
Download 298 pages 18.84 Kb
Page 133
Image 133

4. Maintenance

Sending Test Patterns

Use the Send command to start transmission of a test pattern.

Only one test pattern can be active at a time on one port. Table 4-9, Valid Send Test Pattern Combinations, lists the valid send test pattern combinations. Valid combinations are identified by YES.

Procedure

To send a test pattern:

1.From the top-level menu screen, select Test.

2.From the Test screen, select Ptrns.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3. From the Patterns screen, select Send.

Patterns:

Abort Send Mon

F1 F2 F3

4.From the Patterns Send screen, press F1 to send a QRSS pattern, F2 to send a 1-in-8 pattern, F3 to send a 511 pattern.

Patterns: Send

QRSS 1in8 511

F1 F2 F3

If you send a 1-in-8 pattern, skip Step 5.

5.From the Send screen, press the Function key that corresponds to network or the port for which you want to send a test pattern. Use the scroll keys, if necessary. (NET does not appear for the 511 pattern.)

Send: Name

NET Prt1 Prt2

F1 F2 F3

3160-A2-GB21-90

February 2001

4-31

Page 133
Image 133
Paradyne 3164-A2, 3165-A2, 3160-A3, 3161-B3 manual Sending Test Patterns