C. Configuration Options

Table C-8. Alarm Configuration Options (4 of 4)

AlrmRelay: Disab

Next Enab Disab Prev

Alarm Relay. Specifies whether an alarm condition for this circuit card activates the shared alarm relay on the 3000 Series Carrier. The alarm deactivates if the condition(s) causing it is corrected. An Alarm Cut-Off issued from the SDCP (or PC Emulation program) for a particular carrier-mounted DSU/CSU also deactivates the alarm. The carrier-mounted DSU/CSU does not reactivate the alarm relay until all alarm conditions for the unit are cleared.

he following alarm conditions activate the alarm relay if this configuration option is enabled:

Continuous Loss of Signal (LOS) or Out of Frame (OOF) at the network or DTE Drop/Insert (DSX-1) interface.

Continuous Out of Frame (OOF) at any synchronous data port that has the Embedded Data Link enabled.

Alarm Indication Signal (AIS) received at either the network or DTE Drop/Insert (DSX-1) interface.

Yellow alarm signal received at either the network or DTE Drop/Insert (DSX-1) interface.

TExcessive Error Rate (EER) detected at the network interface.

An Excessive Error Rate (EER) detected at any synchronous data port that has the Embedded Data Link enabled.

NOTE: This configuration option is available on carrier-mounted DSU/CSUs only.

3160-A2-GB21-90

February 2001

C-31