4. Maintenance

Sending a V.54/ANSI FT1 Activation/Deactivation

Procedure

To send a V.54 or ANSI FT1 Activation or Deactivation loopback sequence to the far-end DSU/CSU:

1.From the top-level menu screen, select Test.

2.From the Test screen, select Rlpbk.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3.From the Rem Loopback screen, press the function key that corresponds to the specific loopback test you want to perform. Use the scroll keys, if necessary.

Rem Loopback:

LLBUP LLBDN 54UP

F1 F2 F3

The Rem Loop screen appears.

Rem Loop: Type

Prt1 Prt2 Prt3

F1 F2 F3

The 54UP, 54DN, FT1UP, and FT1DN commands send the requested sequence out the network interface on the DS0 channels allocated to the port you select here.

4.From the Rem Loop screen, press the desired function key to select the specific port. Use the scroll keys, if necessary.

After you select a port, the sequence is sent to the far-end DSU/CSU. During this time, Sending appears on Line 2 of the LCD, followed by Command Complete when the sequence is complete.

During the Sending message, you can press the and keys without affecting transmission of the loopback sequence.

3160-A2-GB21-90

February 2001

4-21

Page 123
Image 123