4. Maintenance

Table 4-4. Enterprise-Specific Trap Definitions

Trap Value

Event

 

 

enterpriseClockFail(1)

The currently configured master clock source has failed.

 

 

enterpriseSelfTestFail(2)

A DSU/CSU hardware failure is detected at self-test. This

 

trap is generated after DSU/CSU initialization.

 

 

enterpriseDeviceFail(3)

An internal DSU/CSU failure is detected by the operating

 

software.

 

 

enterpriseTestStart(5)

A test is initiated.

 

 

enterpriseConfigChange(6)

A configuration option is changed.

 

 

enterpriseTestClear(105)

A test is concluded.

 

 

Table 4-5. SNMP Trap per Interface

Interface

Trap Meaning

 

 

T1 Network

Up = No alarm or test conditions.

 

Down = Alarm or test conditions.

 

 

DTE Drop/Insert (DSX-1)

Up = No alarm or test conditions, and the interface is

 

enabled.

 

Down = Alarm or test conditions, or the interface is

 

disabled.

 

 

Synchronous Data Ports

Up = No test conditions, the port is assigned to a network

 

interface, and both CTS and DSR are ON.

 

Down = Test conditions, the port is unassigned, or either

 

CTS or DSR is off.

 

 

3160-A2-GB21-90

February 2001

4-13

Page 115
Image 115
Paradyne 3161-B3, 3165-A2 manual Enterprise-Specific Trap Definitions Trap Value Event, Snmp Trap per Interface Trap Meaning