4. Maintenance

Aborting Test Patterns

Use the Abort command to stop all test patterns or any selected test pattern active on the DSU/CSU.

Procedure

To abort test patterns:

1.From the top-level menu screen, select Test.

2.From the Test screen, select Ptrns.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3. From the Patterns screen, select Abort.

Patterns:

Abort Send Mon

F1 F2 F3

4.From the Patterns Abort screen, press the desired Function key to abort either All active test patterns, active Send test patterns, or the active Monitor (Mon) test pattern.

Patterns: Abort

All Send Mon

F1 F2 F3

If you select All, the DSU/CSU terminates all active test patterns and displays the message Command Complete. Skip Step 5.

NOTE:

If you mistakenly choose to abort a test pattern that is not currently running, a Command Complete message still displays and the test pattern currently active still runs. Use the TStat branch to view the test status to determine if the abort was successful.

4-34

February 2001

3160-A2-GB21-90

Page 136