4. Maintenance

Starting a Line Loopback

The Line Loopback command (LLB) loops the received signal on the network interface back to the network without change.

DTE

ALL

(DSX-1)

1s

DSU CSU

ALL 1s ALL 1s

LLB

NETWORK

INTERFACE

PORT 2 PORT 1

496-14319-02

 

Procedure

To perform a Line loopback:

1.From the top-level menu screen, select Test.

2.From the Test screen, select Lpbk.

Test:

Rlpbk Lpbk Ptrns

F1 F2 F3

3. From the Loopback screen, select LLB.

Loopback:

Abort LLB PLB

F1 F2 F3

Test Started appears on Line 2. If a line loopback is already in progress, the Already Active message appears. If an invalid combination of loopbacks is in progress, the error message Invld Test Combo appears (see Table 4-8, Valid Loopback Combinations, for valid loopback test combinations).

3160-A2-GB21-90

February 2001

4-23