C. Configuration Options

Alarm Configuration Options

NOTE:

A triangular symbol () identifies a configuration option that is available on carrier-mounted DSU/CSUs only.

Table C-8. Alarm Configuration Options (1 of 4)

Alrm Msg: Disab

Next Disab Modem Com Both Prev

Alarm Messages. Controls the generation of alarm messages, which are routed to an

ASCII terminal or printer attached to the communication port and/or the modem port.

Disab – Prevents an alarm message for any alarm conditions.

Modem – Enables alarm messages routed to the modem port. This selection does not appear on carrier-mounted DSU/CSUs.

Com – Enables alarm messages routed to the communication port.

Both – Enables alarm messages routed to both the modem and communication ports.

This selection does not appear on carrier-mounted DSU/CSUs.

NOTE: Alarm messages are only sent to the communication port if the Com Use configuration option is set to ASCII, otherwise the alarm messages are discarded.

SNMP Trap: Disab

Next Enab Disab Prev

SNMP Trap Enable. Specifies whether SNMP trap messages are sent over the SNMP management link.

Enab – Enables sending SNMP trap messages from this unit over any SNMP management link.

Disab – Disables sending SNMP trap messages from this unit over any SNMP management link.

NOTE: For carrier-mounted DSU/CSUs that have the communication port enabled, the only traps that are disabled are those that pertain to this particular unit. Traps from other units are passed through.

Trap Disc: Enab

Next Enab Disab Prev

SNMP Trap Disconnect. Specifies whether the modem connection or carrier external communication port device connection is disconnected after sending a trap message. This configuration option applies only to modem connections or carrier external communication port device connections initiated as a result of the trap message being sent.

Enab – Specifies that the modem call or carrier external communication port device call is disconnected after a trap message is sent.

Disab – Specifies that the modem call or carrier external communication port device call is not disconnected after a trap message is sent. The line is held until it is manually disconnected or disconnected by the remote modem.

NOTE: This configuration option is only available if SNMP traps are enabled and the integral modem or the carrier external communication port device is enabled and configured as an SNMP management link.