C. Configuration Options

User Interface Configuration Options

NOTE:

A circular symbol () identifies configuration options that are available on standalone DSU/CSUs only. A triangular symbol () identifies configuration options that are available on carrier-mounted DSU/CSUs only.

Table C-7. User Interface Configuration Options (1 of 10)

Self-Test: Enab

Next Enab Disab Prev

Initial Self-Test. Specifies whether the DSU/CSU performs a device self-test at power-up and after a device reset.

Enab – Enables a self-test.

Disab – Disables the self-test.

FP Access: Enab

Next Enab Disab Prev

Front Panel Access. Determines whether front panel access or display is allowed at the

DSU/CSU.

Enab – Allows the front panel to access and display data.

Disab – Prevents the access and display of data.

NOTE: This configuration option is available on standalone DSU/CSUs only.

FP Pass: Disab

Next Enab Disab Prev

Front Panel Pass-Through. Allows dial-out access to a remote DSU/CSU using the front panel pass-through operation.

Enab – Allows dial-out access to a remote DSU/CSU.

Disab – Prevents dial-out access to a remote DSU/CSU.

NOTE: This configuration option is available on standalone DSU/CSUs only.

Dial-In: Enab

Next Enab Disab Prev

Dial-in Access. Allows dial-in access to the DSU/CSU. For standalone DSU/CSUs, dial-in access is through the modem port. For carrier-mounted DSU/CSUs, dial-in access is through an external device that is connected to the communication port.

Enab – Allows dial-in access to the DSU/CSU.

Disab – Prevents dial-in access. Incoming calls to the DSU/CSU are not answered.

NOTE: To enable Dial-In for carrier-mounted DSU/CSUs, the external device must be configured for automatic answer and the ComExtDev configuration option must be enabled.

C-18

February 2001

3160-A2-GB21-90

Page 162