Paradyne 3161-B3, 3165-A2 Performance Reports, Device Health and Status Messages 2 Description

Models: 3160-A3 3165-A2 3161-B3 3164-A2

1 298
Download 298 pages 18.84 Kb
Page 107
Image 107

4. Maintenance

Table 4-2. Device Health and Status Messages (2 of 2)

Message

Description

 

 

Test in progress

A test is currently active. Select Tstat (in the Stat branch) to display

 

more test information.

 

 

Modem

The integral modem is currently connected. This message is only

Connected

displayed for standalone DSU/CSUs.

 

 

Master Clk fail

The master clock has failed. Timing for the DSU/CSU is provided by

 

the internal clock.

 

 

DSU Operational

This message only appears if there are no valid alarm or status

 

messages.

 

 

Performance Reports

When the network interface is configured for ESF operation, network performance is continuously monitored and maintained in two sets of aggregate registers: Carrier Network Interface Registers (Telco) and User Network Interface Registers (User). The User registers contain an extra status register (Status Event). Registers shown on the front panel LCD are listed in Table 4-3, Performance Registers. These registers are status registers that collect performance data for the previous 24-hour period. Performance data is updated in 15-minute intervals. After 15 minutes, the current interval is rolled over into a set of accumulator registers that represent the previous 96 15-minute intervals for the register. An interval total of how many of the 96 registers contain valid data is also kept, as well as a 24-hour total for each accumulator register.

For 2-port and 4-port DSU/CSUs, port performance is continuously monitored and maintained in memory registers when the port is configured to use EDL. The DSU/CSU maintains two sets of port registers for each synchronous data port: far-end port registers and near-end port registers. These registers are status registers that collect performance data for the previous 8-hour period. Port data is updated in 15-minute intervals. After 15 minutes, the current interval is rolled over into a set of accumulator registers that represent the previous 32 15-minute intervals for the register. An interval total of how many of the 32 registers contain valid data is also kept, as well as a 8-hour total for each accumulator register.

NOTE:

The following procedure is an example only. Screen displays may vary depending on the model and configuration of the DSU/CSU. The procedures for displaying Telco and port registers are similar to this example.

3160-A2-GB21-90

February 2001

4-5