E. SNMP MIB Objects

Table E-1. SNMP MIB to Front Panel Command Cross-Reference (2 of 3)

Front Panel Command

SNMP MIB Object

 

 

Stat–>LED–>Prtn:

Read:

DTR

rs232InSigState from rs232InSigName == dtr

CTS

rs232outSigState from rs232OutSigName == ctr

RTS

rs232InSigState from rs232InSigName == rts

 

 

Stat–>ID:

Read the sysDescr object from the System Group

Ser

 

Mod

 

SRev

 

HRevCCA1

 

HRevCCA2

 

 

 

Test–>Rlpbk–>LLBUP

Set dsx1SendCode to dsx1SendLineCode

 

 

Test–>Rlpbk–>LLBDN

Set dsx1SendCode to dsx1SendResetCode

 

 

Test–>Rlpbk–>54UP–>Prtn

Set IfExtnsTestType for port n to testSendV54Up

 

 

Test–>Rlpbk–>54DN–>Prtn

Set IfExtnsTestType for port n to testSendV54Down

 

 

Test–>Rlpbk–>FT1UP–>Prtn

Set IfExtnsTestType for port n to testSendFT1UP

 

 

Test–>Rlpbk–>FT1DN–>Prtn

Set IfExtnsTestType for port n to testSendFT1Down

 

 

Test–>Lpbk–>LLB

Set dsx1LoopbackConfig for Net T1 to dsx1LineLoop

Test–>Lpbk–>Abort–>LLB

Set dsx1LoopbackConfig for Net T1 to dsx1NoLoop

 

 

Test–>Lpbk–>PLB

Set dsx1LoopbackConfig for Net T1 to dsx1PayloadLoop

Test–>Lpbk–>Abort–>PLB

Set dsx1LoopbackConfig for Net T1 to dsx1NoLoop

 

 

Test–>Lpbk–>DLB

Set dsx1LoopbackConfig for DTE T1 to dsx1LineLoop

Test–>Lpbk–>Abort–>DLB

Set dsx1LoopbackConfig for DTE T1 to dsx1NoLoop

 

 

Test–>Lpbk–>RLB

Set dsx1LoopbackConfig for DTE T1 to dsx1PayloadLoop

Test–>Lpbk–>Abort–>RLB

Set dsx1LoopbackConfig for DTE T1 to dsx1NoLoop

 

 

Test–>Lpbk–>DCLB–>Prtn

Set IfExtnsTestType for port n to testFullDuplexLoopBack

Test–>Lpbk–>Abort–>Lpbk–>Prtn

Set dsx1LoopbackConfig for port n to noTest

 

 

Test–>Lpbk–>DTLB–>Prtn

Set IfExtnsTestType for port n to testLoopDTLB

Test–>Lpbk–>Abort–>DTLB–>Prtn

Set dsx1LoopbackConfig for port n to noTest

 

 

Test–>Prtns–>Send–>QRSS–>NET

Set dsx1SendCode for Net T1 to dsx1SendQRSS

Test–>Prtns–>Abort–>Send–>NET

Set dsx1SendCode for Net T1 to dsx1SendNoCode

 

 

Test–>Prtns–>Send–>QRSS–>Prtn

Set IfExtnsTestType for port n to testSendQRS

Test–>Prtns–>Abort–>Send–>Prtn

Set IfExtnsTestType for port n to noTest

 

 

Test–>Prtns–>Send–>1in8

Set dsx1SendCode for Net T1 to dsx1SendOtherTestPattern

Test–>Prtns–>Abort–>Send–>NET

Set dsx1SendCode for Net T1 to dsx1SendNoCode

 

 

Test–>Prtns–>Send–>511–>Prtn

Set IfExtnsTestType for port n to testSend511

Test–>Prtns–>Abort–>Send–>Prtn

Set IfExtnsTestType for port n to noTest

 

 

E-30

February 2001

3160-A2-GB21-90

Page 244
Image 244
Paradyne 3165-A2 manual Set dsx1LoopbackConfig for Net T1 to dsx1LineLoop, Set dsx1LoopbackConfig for Net T1 to dsx1NoLoop