Paradyne 3165-A2, 3164-A2, 3160-A3, 3161-B3 Table C-5. Data Port Channel Configuration Options 1

Models: 3160-A3 3165-A2 3161-B3 3164-A2

1 298
Download 298 pages 18.84 Kb
Page 156
Image 156

C. Configuration Options

Table C-5. Data Port Channel Configuration Options (1 of 4)

Channel Config:

Dsply Clear DTE Prt1 Prt2 Prt3 Prt4

_______________________

NOTE: The configuration options described in this table are made available by selecting Prt1, Prt2, Prt3, or Prt4 from the Channel Config screen. Table C-4, DTE Channel Configuration Options, describes the DTE configuration options. For information about the operation of Display and Clear, refer to Configuring DS0 Channels in Chapter 3, Operation.

Data Port Channel. Allows the assignment of a particular port to DS0 channels on either the network interface, the DTE Drop/Insert (DSX-1) interface, or another port (see the Assign To configuration option below).

NOTE: For 2-port DSU/CSUs, only Ports 1 and 2 are available; for 1-port DSU/CSUs, only Port 1 is available, and only the Port Rate configuration option appears if you select this port.

Assign To: NET

Next NET DTE Prtn Prtn Prtn Prev

Data Port Channel Allocation Destination. Allows you to assign this port to DS0 channels on either the network interface, the DTE Drop/Insert (DSX-1) interface, or another port.

NET – Assigns this port to DS0 channels on the network interface.

DTE – Assigns this port to DS0 channels on the DTE Drop/Insert (DSX-1) interface. If the DTE Drop/Insert (DSX-1) interface is disabled, this selection does not appear.

Prtn – Assigns this port to another port, where n is the port number of all available ports except the port selected from the Channel Config screen. For example, if you select Prt1 from the Channel Config screen, Prt2, Prt3, and Prt4 appear for 4-port DSU/CSUs. Use this feature to designate a port as a backup port. You can attach an external backup device to Prtn and manually assign the selected port to the backup port (i.e., route data from the selected port to the backup port). When a port is assigned to another port, DSR is turned on. Selecting Prtn and Next takes you directly to the Port Rate configuration option, bypassing the Assign By configuration option. EDL (for 2-port and 4-port DSU/CSUs) does not operate when a synchronous data port is assigned to another synchronous data port. Therefore, if EDL is enabled, it is ignored.

NOTE: Changing this configuration option from one T1 interface to the other (NET or

DTE) deallocates all DS0 channels assigned to the previous interface.

Assign By: Block

Next Block ACAMI Chan Prev

Data Port Channel Allocation Method. If NET or DTE is selected using the Assign To configuration option, this configuration option designates the method for assigning DS0 channels to the destination T1 interface.

Block – Allocates DS0 channels to this port by the block method.

ACAMI – Allocates DS0 channels to this port by the Alternate Channel Alternate Mark Inversion method. The difference between block and ACAMI is that the number of channels allocated with ACAMI is double the number needed for the port rate. With ACAMI, every alternate DS0 channel does not carry data from the port but always transmits and receives all ones.

Chan – Allocates DS0 channels to this port by the individual channel method.

NOTE: Changing this configuration option from one method to another (Block, ACAMI, or Chan) deallocates all DS0 channels assigned to either the network interface or the DTE Drop/Insert (DSX-1) interface.

C-12

February 2001

3160-A2-GB21-90

Page 156
Image 156
Paradyne 3165-A2 Table C-5. Data Port Channel Configuration Options 1, Channel Config Dsply Clear DTE Prt1 Prt2 Prt3 Prt4