C. Configuration Options
3160-A2-GB21-90 February 2001 C-21
ComConnected:
Next Edit Clear Prev
Carrier Communication Port Connect Indication String. Specifies the communication
ports connect indication string. When you make a connection or the DSU/CSU
automatically makes a connection (dial-out alarms or traps) through the communication
port, this string determines that the connection has been established. The connect
indication string is an ASCII text string and may be up to 20 characters in length. If the
connect indication string is not received within 1 minute, it will time-out the connection. If
the connect indication string is NULL, the communication ports receive data stream is not
searched and a transition in the Carrier Detect (CD) lead is used to determine that a
connection has been established.
Edit Allows you to edit and/or display the case-sensitive connect indication string using
the generic text string entry screen.
Clear Allows you to clear the connect indication string. The connect indication string is
set to a null string.
NOTES:
This configuration option is available on carrier-mounted DSU/CSUs only.
This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
ComEscapeSeq:
Next Edit Clear Prev
Carrier Communication Port Escape Sequence. Specifies the communication ports
escape sequence. Once the external device connection has been establish ed, eit her you
or the DSU/CSU can command the external device to disconnect. Before doing so, you
may need to send the escape sequence out to switch the external device into command
mode. The escape sequence is an ASCII text string and may be up to 20 characters in
length. If the escape sequence is NULL, no escape sequence is sent out.
Edit Allows you to edit and/or display the escape sequence using the gen eric text string
entry screen.
Clear Allows you to clear the escape sequence. The escape sequence is set to a null
string.
NOTES:
This configuration option is available on carrier-mounted DSU/CSUs only.
This configuration option is not available if the ComExtDev configuration option is
set to AT or the communication port is disabled.
Table C-7. User Interface Configuration Options (4 of 10)