4. Maintenance

Test Jacks

For 2-port and 4-port DSU/CSUs, six test jacks are located on the front panel

(Figure 4-1, Test Jacks (Standalone DSU/CSU)). The Mon (Monitor) branch of the menu tree allows you to select either EQPT (Equipment) or NET (Network).

The 2-port and 4-port DSU/CSU test jack functions are shown in Figure 4-2, Test Jack Block Diagram, and described in Table 4-7, Test Jack Functions.

NET MON EQPT

In

In

In

Out

Out

Out

 

 

496-14808

Figure 4-1. Test Jacks (Standalone DSU/CSU)

Procedure

To change the Mon (Monitor) selection in 2-port and 4-port DSU/CSUs:

1.From the top-level menu, press the key until the Ctrl selection appears on the screen.

2.Select Ctrl.

3.From the Control screen, press the key until the Mon selection appears on the screen.

4.Select Mon.

Control:

Passwd Mon

F1 F2 F3

5.From the Mon Jack screen, press F1 to select EQPT (the default), or press F2 to select NET.

Mon Jack: EQPT

EQPT NET

F1 F2 F3

3160-A2-GB21-90

February 2001

4-17

Page 119
Image 119
Paradyne 3161-B3, 3165-A2, 3164-A2, 3160-A3 manual Test Jacks, Eqpt NET