C. Configuration Options
3160-A2-GB21-90 February 2001 C-23
Com Clk: Int
Next Int Ext Prev
Communication Port Synchronous Clock. Specifies whether the comm uni catio n port uses
internal or external clocking when it is configured for synchronous operation.
Int Configures the communication port for internal clocking.
Ext Configures the communication port for external clocking.
NOTES:
This configuration option is available on standalone DSU/CSUs only.
This configuration option is not available if the Com Type configuration option is set
to Async.
Com Rate: 9.6
Next 1.2 2.4 4.8 9.6 14.4 19.2 38.4 Prev
Communication Port Rate. Configures the bit rate for the communication port.
1.2 Sets the bit rate to 1200 bps (for asynchronous operation only).
2.4 Sets the bit rate to 2400 bps.
4.8 Sets the bit rate to 4800 bps.
9.6 Sets the bit rate to 9600 bps.
14.4 Sets the bit rate to 14,400 bps.
19.2 Sets the bit rate to 19,200 bps.
38.4 Sets the bit rate to 38,400 bps. This rate is not supported for carrier-mounted
DSU/CSUs.
NOTE: This configuration option is not ava ilab le if the comm unica tion port is co nfigured
for synchronous operation and the clock source is external.
Char Length: 8
Next 7 8 Prev
Communication Port Character Length. Configures the character length (7 or 8 bits) for
the communication port.
NOTES:
This configuration option must be set to 8 if the communication port is used as the
network communication link.
This configuration option is not available if the communication port is configured for
synchronous operation.
CParity: None
Next None Even Odd Prev
Communication Port Parity. Configures the parity (none, even, or odd) for the
communication port.
NOTE: This configuration option is not ava ilab le if the comm unica tion port is co nfigured
for synchronous operation.
Table C-7. User Interface Configuration Options (6 of 10)