C. Configuration Options

Table C-7. User Interface Configuration Options (6 of 10)

Com Clk: Int

Next Int Ext Prev

Communication Port Synchronous Clock. Specifies whether the communication port uses internal or external clocking when it is configured for synchronous operation.

Int – Configures the communication port for internal clocking.

Ext – Configures the communication port for external clocking.

NOTES:

This configuration option is available on standalone DSU/CSUs only.

This configuration option is not available if the Com Type configuration option is set to Async.

Com Rate: 9.6

Next 1.2 2.4 4.8 9.6 14.4 19.2 38.4 Prev

Communication Port Rate. Configures the bit rate for the communication port.

1.2– Sets the bit rate to 1200 bps (for asynchronous operation only).

2.4– Sets the bit rate to 2400 bps.

4.8– Sets the bit rate to 4800 bps.

9.6– Sets the bit rate to 9600 bps.

14.4– Sets the bit rate to 14,400 bps.

19.2– Sets the bit rate to 19,200 bps.

38.4– Sets the bit rate to 38,400 bps. This rate is not supported for carrier-mounted DSU/CSUs.

NOTE: This configuration option is not available if the communication port is configured for synchronous operation and the clock source is external.

Char Length: 8

Next 7 8 Prev

Communication Port Character Length. Configures the character length (7 or 8 bits) for the communication port.

NOTES:

This configuration option must be set to 8 if the communication port is used as the network communication link.

This configuration option is not available if the communication port is configured for synchronous operation.

CParity: None

Next None Even Odd Prev

Communication Port Parity. Configures the parity (none, even, or odd) for the communication port.

NOTE: This configuration option is not available if the communication port is configured for synchronous operation.

3160-A2-GB21-90

February 2001

C-23

Page 167
Image 167
Paradyne 3161-B3, 3165-A2, 3164-A2, 3160-A3 Table C-7. User Interface Configuration Options 6, Com Clk Int Next Int Ext Prev