C. Configuration Options

Table C-7. User Interface Configuration Options (3 of 10)

ComExtDev: Disab

Next Disab AT Other Prev

Carrier Communication Port’s External Device Commands. Specifies the communication port’s external device commands. When this configuration option is disabled, no commands are sent out the communication port. Select AT to have standard attention (AT) commands sent out the communication port to control the external device. Select Other to configure the connect prefix, the connect indication string, the escape sequence, the escape sequence delay, and the disconnect string.

Disab – Allows no commands to be sent out the communication port.

AT – Allows standard AT commands to be sent out the communication port.

Other – Allows user configurable commands to be sent out the communication port.

NOTES:

This configuration option is available on carrier-mounted DSU/CSUs only.

This configuration option is not available if the communications port is disabled.

Carrier Detect (CD) is used to detect that the external device’s connection is lost. Therefore, do not allow the CD lead to be forced on by the external device.

The external device should be strapped to ignore Data Terminal Ready (DTR).

ComConnPrefix:

Next Edit Clear Prev

Carrier Communication Port Connect Prefix. Specifies the connect prefix to the dial directory phone number. When you make a connection or the DSU/CSU automatically makes a connection (dial-out alarms or traps) through the communication port, the connect prefix and the dial directory phone number are used to establish the connection. The connect prefix is an ASCII text string and may be up to 20 characters in length. If the connect prefix is NULL, then no connect prefix is used.

Edit – Allows you to edit and/or display the connect prefix using the generic text string entry screen.

Clear – Allows you to clear the connect prefix. The connect prefix is set to a null string.

NOTES:

This configuration option is available on carrier-mounted DSU/CSUs only.

This configuration option is not available if the ComExtDev configuration option is set to AT or the communication port is disabled.

If ComExtDev is configured for Other and the external device requires characters after the dial phone number, you must append the characters to the phone number.