Chapter 4 | Diagnostics |
0020 An ISA accessory board reports an initialization problem.
The ROM on the accessory board is either bad, or the board is conflicting with a system board reserved resource (address, DMA or IRQ).
1.Change the resources used by the ISA accessory boards.
2.Try to disable (free) resources used by system board devices.
3.If the problem persists, the accessory board may be defective. Contact the accessory board vendor.
0040 The HP NetServer Serial Number has been lost or has not been initialized.
Pressing [F2] will automatically run the HP Serial Utility and allow you to enter the Serial Number.
0041 Internal data, the product type, has been lost or has not been initialized.
Pressing [F2] will automatically run the HP Product Utility and allow you to
0060 The network remote
It will not be possible to remotely
1.Check that the internal flat cable is firmly connected on the system board and on the integrated LAN interface.
2.Power off the HP NetServer and disconnect the power cords for a few seconds.
0070 The Smart Interrupt Router FPGA failed to initialize. This problem prevents your system from booting and operating. If the error persists, replace the system board.
0071 The data for the Smart Interrupt Router FPGA is corrupted. This problem prevents your system from booting and operating. If the error persists, replace the BIOS ROM Chip.
0075 The firmware for the Integrated HP NetRAID is not responding. This problem prevents the operation of the Integrated HP NetRAID.
To correct this problem, flash the Integrated HP NetRAID firmware and reboot the system.
If the error persists, replace the I/O board.
0080 The HP NetServer Management Controller failed its self-test.
Due to this failure remote access and server management event logging are not available.
•To correct this problem reset the Management Controller by powering off the HP NetServer and disconnecting the power cords for 20 seconds. Reconnect the power cords and power on the HP NetServer.
OR,
•Update the system BIOS by running the flash utility from the HP NetServer Navigator
If the error persists, your Power Management/Interconnection board may need to be replaced. Contact your service representative.
49