Parameter # | Description | Units |
24
25
26
27
Calling tone maximum OFF time. Maximum period of silence that1ms |
|
| |||
between CNG tones for the tone sequence to be valid. | (1000 ms to |
|
| ||
Country | Default | 15000 ms) |
|
| |
United States | 8000 |
|
|
|
|
Australia | 8000 |
|
|
|
|
France | 8000 |
|
|
|
|
Germany | 8000 |
|
|
|
|
Netherlands | 8000 |
|
|
|
|
United Kingdom | 8000 |
|
|
|
|
India | 8000 |
|
|
|
|
Korea | 8000 |
|
|
|
|
China | 8000 |
|
|
|
|
Calling tone maximum dropout time. Maximum duration of | 1 ms |
| can | ||
interrupt a CNG tone. If the dropout is less than this time, then(0 ms to |
| will | |||
be processed as a single continuous tone. | 500 ms) |
|
| ||
Country | Default |
|
|
| |
United States | 100 |
|
|
|
|
Australia | 100 |
|
|
|
|
France | 100 |
|
|
|
|
Germany | 100 |
|
|
|
|
Netherlands | 100 |
|
|
|
|
United Kingdom | 100 |
|
|
|
|
India | 100 |
|
|
|
|
Korea | 100 |
|
|
|
|
China | 100 |
|
|
|
|
|
|
| |||
Calling tone minimum count. Minimum number of CNG tones that1 | tone (1 tone | ||||
detected for an incoming fax to be detected. | to 15 tones) |
| |||
Country | Default |
|
|
| |
United States | 2 |
|
|
| |
Australia | 2 |
|
|
|
|
France | 1 |
|
|
|
|
Germany | 2 |
|
|
|
|
Netherlands | 2 |
|
|
| |
United Kingdom | 2 |
|
|
|
|
India | 2 |
|
|
|
|
Korea | 2 |
|
|
|
|
China | 2 |
|
|
|
|
Calling tone detect threshold. Sets the detection threshold10 |
|
|
| ||
| received CNG | ||||
tone. If the CNG tone is below this level it will not be detected(260 | to 510) |
|
| ||
Country | Default |
|
|
| |
United States | 350 |
|
|
| |
Australia | 350 |
|
|
|
|
France | 450 |
|
|
| |
Germany | 350 |
|
|
| |
Netherlands | 350 |
|
|
| |
United Kingdom | 350 |
|
|
| |
India | 450 |
|
|
| |
Korea | 350 |
|
|
| |
China | 450 |
|
|
| |
|
|
|
|
|
|
Problem