Commercial Pool Heaters
INSTALLATION Continued
Ensure that the pump installed on the pool heater will supply adequate flow to make the flow switch contacts and operate the pool heater. A water flow switch meets most code requirements for a
PUMP PURGE / MAINTENANCE TIMER OPTION
Pump Purge Delay Option
An electronic pump purge option is available for this pool heater. During extended periods of inactivity during which pumping may have been turned off to conserve energy, air can become entrapped in the piping. The pump purge option delays pool heater operation until the pump has been on for sufficient time to remove air from piping. Both the inactivity time and pump purging time are adjustable.
The inactive timer is adjustable from 1 - 99 hours. Selection of a time between 4 - 8 hours is recommended.
The purge timer is adjustable from 1 - 60 minutes. Selection of a time between 10 to 30 minutes is recommended.
An override toggle switch is provided to turn off the pump purge feature for testing or should the option no longer be desired. When turned off, the call for heat will not be delayed.
Service Indicator Option
A service indicator option is available for this pool heater. The Service Indicator light on the Diagnostic Information Panel will light up indicating that the
CONNECTING TO
ELECTRICAL SUPPLY
This pool heater is wired for 120 VAC service. The pool heater, when installed, must be electrically grounded in accordance with the requirements of the authority having jurisdiction or in the absence of such requirements, with the latest edition of the National Electrical Code ANSI/NFPA No. 70. When the pool heater is installed in Canada, it must conform to the CAE C22.1, Canadian Electrical Code, Part 1 and/or local Electrical Codes.
1.Use only
2.Enclose line voltage wire exterior to the pool heater in approved conduit or approved
3.The pump must run continuously when the pool heater is being fired.
4.To avoid serious damage, do not energize the pool heater until the system is filled with water.
5.Provide the pool heater with the proper overload protection.
IMPORTANT: Do not block access to the electrical cover plate when installing electrical conduit.
3-Way Automatic Bypass Valve Wiring
If the piping loop was disassembled for shipping or needs to be fitted with an outdoor enclosure, connection or disconnection of the
-Yellow to terminal #1
-Blue to terminal #2
-White with a red stripe to terminal #3
-Pink to terminal #4.
Note: Orientation of the valve connections may vary from what is shown. Care should be taken to ensure wires are connected to the appropriate terminals, see Figure 33 on page 32 of this manual.
WARNING: Power must be removed and the clutch button must be depressed before attempting to manually operate the valve or damage to the
36