Olympus M1200 manual Turquoise

Page 10

How To Change the Metering Tip:

Remove the chemical feed hose from the barb on the side of the proportioning valve.

Unscrew and remove the old tip.

Screw in the proper tip for your chemical tip and place the hose back on the barb

Proportioning Valve

Turquoise Tip

Dilution 256 - 1

Red Tip

Dilution 85 - 1

Metering Tip Kit – PDE001

Metering Tip Kit (Hydro-Force Item# PDE001) contains 14 different colored metering tips, allowing dilution rates from 11:1 up to 427:1. Refer to the chart below to select the tip that meets the dilution rate for your chemical application.

For example: if you require 1-1/2 ounces of chemical per gallon of water, change to the red metering tip with the dilution rate of 85:1.

The dilution rates are based on chemicals with water-like viscosity. Thicker (more viscous) chemicals will dilute at a different rate.

For powdered chemicals, a liquid concentrate must be made. Mix the concentrate according to the manufacturer’s directions, and then select the appropriate metering tip.

Contact your distributor or Hydro-Force if you have questions about your chemical.

Metering Tip Application Chart:

TIP

CHEMICAL DILUTION RATES

COLOR

OZ / GAL

(RATIO)

 

 

 

 

 

 

TAN

0.30

(427:1)

 

 

 

 

 

ORANGE

0.40

(320:1)

 

TURQUOISE

0.50

(256:1)

 

 

 

 

 

PINK

0.75

(170:1)

 

LIGHT BLUE

1.00

(128:1)

 

BROWN

1.12

(114:1)

 

RED

1.50

(85:1)

 

 

 

 

 

WHITE

1.75

(73:1)

 

GREEN

2.00

(64:1)

 

BLUE

2.50

(51:1)

 

YELLOW

3.75

(34:1)

 

 

 

 

 

BLACK

5.00

(26:1)

 

PURPLE

8.50

(15:1)

 

GRAY

11.50

(11:1)

 

NO TIP

16.25

(8:1)

10

Image 10
Contents Revised Table of Contents Introduction M1200 High Pressure Extractor Power Cords 50’ x 12gauge with male & female plug endsPump-out Hose Additional / Optional Equipment AH79DSafety Page SET UP and Operation Electrical Cords2A. Water Supply & Chemical Mixing- Manual Fill 2B. Water Supply & Chemical Dilution Auto-FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Solution Hose Connection of Vacuum HosesHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Troubleshooting Olympus M1200Problem Cause Solution Problem Cause Solution M1200 Solution Flow Path Pump AP48M1200 Wiring Diagram Waste Pump Solution Vacuum #2 Vacuum #1Page Olympus Switch Panel Maintenance Operation IntervalClean Chemical Feed Filter & Foot Valve Clean Vacuum Shutoff Assembly ScreenClean the HYDRO-FILTER Rinse OUT Recovery TankPage Clean Pump Inlet Filter Flush Chemical System Lubricate Pressure Regulator O-RINGS LatchPage Clean Recovery Tank Drain Flange FittingStorage Prep and Freeze Protection Procedures Parts M1200 Pump AP48Pumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty