2A. Water Supply & Chemical Mixing– Manual Fill:

Pour up to 12 gallons of hot water into the solution tank at the front of the machine. The water temperature cannot exceed 180°F.

Measure and add the appropriate amount of the desired liquid chemical to the water in the solution tank. The amount of chemical will vary depending on the type of chemical used, the amount of water in the tank, and the material being cleaned; consult the chemical packaging for specific mixture ratios.

Powdered chemicals should be dissolved in water before adding to the water in the solution tank.

DO NOT RUN OUT OF WATER WHILE USING THE MACHINE! Ensure that the tank contains enough water to complete each job. If the water level is low: stop cleaning, turn off the pump, and refill the tank. Running the pump dry will damage the pump and void the warranty.

Pour appropriate amount of hot water into solution tank

Add appropriate amount of chemical to water in solution tank

2B. Water Supply & Chemical Dilution – Auto-Fill:

The chemical dilution rate is controlled by the metering tip, and the dilution rate can only be changed by changing the metering tip (See “How to Change the Metering Tip” on Page 10 for instructions.)

Chemical Feed Setup:

Remove the chemical feed hose from the solution tank.

Place the end of the hose into a container of liquid chemical.

If the tip is removed, and the proportioning system operated with no tip, the dilution rate will be 8:1 (the equivalent to adding 16-1/4oz of chemical to each gallon of water.)

The standard tip included with the M1200 is the turquoise tip with a dilution rate of 256:1. This means that for each gallon of water flowing into the machine, 1/2 ounce of chemical will be added.

If a fresh water rinse with no chemical is desired, simply leave the chemical feed hose inside the solution tank.

Proportioning Valve

Chemical Feed Hose

9

Image 9
Contents Revised Table of Contents Introduction Power Cords 50’ x 12gauge with male & female plug ends M1200 High Pressure ExtractorPump-out Hose AH79D Additional / Optional EquipmentSafety Page Electrical Cords SET UP and Operation2B. Water Supply & Chemical Dilution Auto-Fill 2A. Water Supply & Chemical Mixing- Manual FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Vacuum Hoses Connection of Solution HoseHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Olympus M1200 TroubleshootingProblem Cause Solution Problem Cause Solution Pump AP48 M1200 Solution Flow PathWaste Pump Solution Vacuum #2 Vacuum #1 M1200 Wiring DiagramPage Olympus Switch Panel Operation Interval MaintenanceClean Vacuum Shutoff Assembly Screen Clean Chemical Feed Filter & Foot ValveRinse OUT Recovery Tank Clean the HYDRO-FILTERPage Clean Pump Inlet Filter Flush Chemical System Latch Lubricate Pressure Regulator O-RINGSPage Flange Fitting Clean Recovery Tank DrainStorage Prep and Freeze Protection Procedures M1200 Pump AP48 PartsPumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty