7. Pressure Adjustment:

When the high-pressure solution pump is on and primed, pressure will show on the gauge only while the tool is being sprayed. When the tool is sprayed the gauge will display the pressure being delivered to the tool. When the tool is not being sprayed the gauge will return to zero.

To decrease the pressure, turn the black knob on the pressure regulator to the left (counter- clockwise.)

To increase the pressure, turn the black knob on the pressure regulator to the right (clockwise.)

To adjust pressure to your tool and surface requirements:

oSpray the tool.

oCheck the pressure on the gauge.

oRe-adjust as needed to set the machine at the desired pressure.

oChoose the pressure setting that best meets your type of cleaning.

To increase the solution pressure, turn the regulator knob clockwise.

To decrease the solution pressure, turn the regulator knob counter-clockwise.

The maximum pressure setting is 1200psi; however, the highest pressure attained is dependent on the amount of water flow at the tool:

Smaller jets and lower flow will allow for higher pressure at the tool.

Larger jets and higher flow will lower the maximum pressure attained at the tool.

The desired setting will depend on the type of cleaning and tool used. For example:

Carpet Cleaning with 2-jet AW29 wand: 400psi

Tile Cleaning with SX-12: 1000psi

If adjusting or maintaining pressure becomes a problem, refer to the trouble shooting guide or contact your distributor for advice or assistance.

Pressure gauge

16

Image 16
Contents Revised Table of Contents Introduction M1200 High Pressure Extractor Power Cords 50’ x 12gauge with male & female plug endsPump-out Hose Additional / Optional Equipment AH79DSafety Page SET UP and Operation Electrical Cords2A. Water Supply & Chemical Mixing- Manual Fill 2B. Water Supply & Chemical Dilution Auto-FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Solution Hose Connection of Vacuum HosesHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Troubleshooting Olympus M1200Problem Cause Solution Problem Cause Solution M1200 Solution Flow Path Pump AP48M1200 Wiring Diagram Waste Pump Solution Vacuum #2 Vacuum #1Page Olympus Switch Panel Maintenance Operation IntervalClean Chemical Feed Filter & Foot Valve Clean Vacuum Shutoff Assembly ScreenClean the HYDRO-FILTER Rinse OUT Recovery TankPage Clean Pump Inlet Filter Flush Chemical System Lubricate Pressure Regulator O-RINGS LatchPage Clean Recovery Tank Drain Flange FittingStorage Prep and Freeze Protection Procedures Parts M1200 Pump AP48Pumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty