Knowledge of the proper operation of the M1200 is required to ensure user safety and efficient performance of the extractor.
SET UP AND OPERATION
1. Electrical Cords:
Two 50’ power cords are supplied with the Olympus M1200. Cord #1 powers both vacuum motors; Cord #2 powers the high pressure solution pump and the waste pump. The amperage required by each cord requires that the two cords be plugged into separate circuits:
•Cord #1 (right side) will require a 20amp circuit to run both vacuums.
•Cord #2 (left side) can be plugged into a 15 amp circuit if Auto
circuit if the Auto
20amp circuits are usually found in kitchens and bathrooms. Plug the two power cords into two outlets from different circuits.
If you are not sure if you are connected to separate circuits, use a Breaker Buddy , included with your machine, to test your circuits in the following manner:
•Plug the cords into the two outlets being tested, and then plug the two cords into your machine.
•If the green Breaker Buddy indicator light fails to light, you may be on the same circuit and must select a different plug for one of the cords.
•If the green indicator light comes on, you are plugged into two different circuits, and may proceed
with your
If a circuit breaker trips during operation, reset the breaker and move the cord to another outlet as needed.
Cord #1
Cord #2
Power Cord – AX33
50’ – 12 gauge
8