10.Apply thread sealant to the threads of the stem retainer and screw the retainer back into the regulator body. Tighten using wrenches.
Apply thread sealant to stem retainer
Screw stem retainer back into regulator body
11.Place the regulator back into the opening on the base wall. Reconnect any hoses which were removed to access the regulator. (Use thread sealant when reconnecting hoses.)
12.Reconnect vacuum hose to vacuum manifold.
Vacuum Hose – Connected to Vacuum Manifold
Regulator – Inserted into opening on base wall
13.Close tanks back onto base and secure latch.
14.Place washer and jam nut back onto shoulder of regulator and tighten to secure regulator to base wall.
15.Replace spring washer, spring, and spring plate back onto regulator stem.
16.Screw black knob back onto regulator stem.
17.Screw nut back onto regulator stem. Do not screw nut on too far, as the nut may interfere with the movement of the regulator knob and prevent the knob from being backed out when trying to adjust regulator to lower pressures.