2Section
Troubleshooting
Troubleshooting –
Olympus M1200
| Problem | Cause | Solution |
| Machine not | Building circuit breaker tripped. | Reset breakers or move cords to other outlets |
| turning on - | Faulty power cord | Replace cord |
| No power | Faulty switches or internal wiring | Check wiring & test switches - Repair as needed * |
|
|
|
|
| Solution |
|
|
| Pump | Building circuit breaker tripped. | Reset breakers or move cords to other outlets |
| not running | Faulty power cord | Replace cord |
|
| Faulty switches or internal wiring | Check wiring & test switches - Repair as needed * |
|
| Pump motor breaker tripped | Push in reset button on pump motor |
|
| Pump motor faulty | Replace pump motor |
|
| Pump seized - trips breaker | Repair or replace pump head & bearing - Check motor |
|
|
|
|
|
|
| Check jets size & flow rates use smaller jets or lower |
| Low Solution | Jets too large for pressure desired | pressure |
| Pressure |
|
|
| and/or | Jets worn allowing too much flow | Replace jets |
| Pulsation | Solution inlet filter plugged | Clean or replace filter |
|
| Hose from solution tank restricted | Repair or replace hose |
|
| Pump intake hose or fittings |
|
|
| leaking | Repair or replace hose. Tighten clamps or replace fittings |
|
| Pressure regulator sticking | Lube |
|
| Pressure regulator faulty | Repair or replace pressure regulator |
|
| Filter screen or jets plugged on |
|
|
| tool | Clean out filter or jets |
|
| Solution tank empty | Add water to tank - Check & repair auto fill assembly |
|
| Pump not primed | Perform pump priming procedure |
|
| Pump faulty | Repair or replace pump |
|
| Pressure Gauge faulty | Replace gauge |
|
| Tool valve faulty | Repair or replace valve |
|
| Quick connects or hoses restricted | Clean out or replace quick connects and/or hoses |
|
|
|
|
| Can't connect | Pressure in lines | Release pressure |
| solution hose | Quick connects faulty | Replace quick connects |
| to machine | Wrong style/size quick connects | Replace quick connects to match connects on machine |
|
|
|
|
*To reduce the risk of fire electrical shock or injury repairs to wiring should only be performed by experienced service technicians.
If you are not experienced in checking electrical wiring contact your nearest authorized service center to perform tests and repairs to wiring and switches.
18