Olympus M1200 manual Clean the HYDRO-FILTER, Rinse OUT Recovery Tank

Page 27

CLEAN THE HYDRO-FILTER:

Build-up of debris in the filter bag of the Hydro-Filter will reduce the vacuum air flow and may cause a significant decrease in water recovery. A torn filter bag will allow debris past the filter and into the recovery tank. This debris can clog the Waste Pump and the Vacuum Shutoff Assembly. The Hydro-Filter must be examined and cleaned regularly to keep the M1200 functioning properly:

Push the latch lever and open the Hydro-Filter lid.

Remove the filter bag. Examine the bag and clean or replace as needed.

Rinse the body of the Hydro-Filter with clean water.

Examine the o-ring seal and replace as needed.

Re-install the new or cleaned bag.

Close lid and secure latch.

Repair parts are available for the Hydro-Filter:

Filter Bag:

AC11A

 

 

 

 

 

 

Parts Kit:

AC11B – (Includes Latch, O-ring & screws.)

 

 

 

Lid:

AC11D

 

 

FILTER BAG – AC11A

 

 

 

 

 

 

 

 

 

LID – AC11D

O-RING

LATCH

FILTER BODY

RINSE OUT RECOVERY TANK:

Build-up of fine silt and debris can damage the Waste Pump and Drain Valve. Clean out the tank on a regular basis to extend the life of these components as well as keep the tank and machine smelling better.

Remove the recovery tank lid and open the drain valve.

Place a bucket under the drain valve.

Use a hose to rinse the dirt and debris out of the recovery tank.

Close the drain valve and spray the tank with a deodorizer or disinfectant.

Proceed to Waste Pump Cleaning and replace the recovery tank lid.

Dispose of the dirty water and debris.

27

Image 27
Contents Revised Table of Contents Introduction Power Cords 50’ x 12gauge with male & female plug ends M1200 High Pressure ExtractorPump-out Hose AH79D Additional / Optional EquipmentSafety Page Electrical Cords SET UP and Operation2B. Water Supply & Chemical Dilution Auto-Fill 2A. Water Supply & Chemical Mixing- Manual FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Vacuum Hoses Connection of Solution HoseHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Olympus M1200 TroubleshootingProblem Cause Solution Problem Cause Solution Pump AP48 M1200 Solution Flow PathWaste Pump Solution Vacuum #2 Vacuum #1 M1200 Wiring DiagramPage Olympus Switch Panel Operation Interval MaintenanceClean Vacuum Shutoff Assembly Screen Clean Chemical Feed Filter & Foot ValveRinse OUT Recovery Tank Clean the HYDRO-FILTERPage Clean Pump Inlet Filter Flush Chemical System Latch Lubricate Pressure Regulator O-RINGSPage Flange Fitting Clean Recovery Tank DrainStorage Prep and Freeze Protection Procedures M1200 Pump AP48 PartsPumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty