FLUSH SOLUTION TANK AND PUMP: (continued from previous page)

Direct the end of the prime hose into

the recovery tank vacuum barb

CLEAN PUMP INLET FILTER

Vacuum acid solution out of

Solution Tank

A restricted Pump Inlet Filter can prevent the solution pump from providing adequate pressure for cleaning. A restriction or air leak on the pump inlet can also damage the solution pump check valves and plunger seals.

CAUTION: Before proceeding with this procedure, make sure both power cords are disconnected.

To examine the filter, release the latch on the front of the machine and tilt the tanks off of the base assembly. Support the tanks with a chair, bucket or box while working inside the base.

The filter is in the clear 1/2” ID hose from the solution tank to the inlet port on the solution pump.

Grasp the clear plastic filter cap and unscrew the cap from the black plastic filter body by turning counter-clockwise.

Remove the stainless steel filter screen and clean as needed.

Examine the cap and body for cracks and replace filter as needed. (Replacement Filter: PPU6175)

Check the gasket for nicks or tears and replace filter as needed.

Reassemble filter and check hose clamps and tighten as needed.

Tilt the tanks back onto the base and secure the latch.

Latch

Solution Tank

INLINE FILTER

PPU6175

Base

29

Image 29
Contents Revised Table of Contents Introduction Pump-out Hose Power Cords 50’ x 12gauge with male & female plug endsM1200 High Pressure Extractor AH79D Additional / Optional EquipmentSafety Page Electrical Cords SET UP and Operation2B. Water Supply & Chemical Dilution Auto-Fill 2A. Water Supply & Chemical Mixing- Manual FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Vacuum Hoses Connection of Solution HoseHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Olympus M1200 TroubleshootingProblem Cause Solution Problem Cause Solution Pump AP48 M1200 Solution Flow PathWaste Pump Solution Vacuum #2 Vacuum #1 M1200 Wiring DiagramPage Olympus Switch Panel Operation Interval MaintenanceClean Vacuum Shutoff Assembly Screen Clean Chemical Feed Filter & Foot ValveRinse OUT Recovery Tank Clean the HYDRO-FILTERPage Clean Pump Inlet Filter Flush Chemical System Latch Lubricate Pressure Regulator O-RINGSPage Flange Fitting Clean Recovery Tank DrainStorage Prep and Freeze Protection Procedures M1200 Pump AP48 PartsPumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty