FLUSH CHEMICAL SYSTEM:

Chemical build-up in the chemical system can prevent the system from drawing chemical.

Rinse the chemical system with fresh water (For heavy chemical build- up, a mild acid can be added to the rinse water.)

Remove the chemical feed hose from the solution tank and place the end of the hose in a bucket of fresh water or mild acid solution.

Place Chemical Feed Hose into Rinse Solution

Connect the Auto-Fill Water Supply Hose to the water inlet (male quick connect) on the front of the machine.

Connect the other end of the hose to a water faucet and turn on the water. Let the water flow into the tank until you are sure the rinse solution has been drawn through the proportioner and mixed with the incoming water. The metering tip can be removed from the proportioner to speed up the process.

Once the rinse solution has been drawn through the proportioner, turn off the water faucet and disconnect the Auto-Fill Water Supply Hose.

Plug in Cord #1, connect the short 4’ vacuum hose to the vacuum barb, turn on one or both vacuums, and use the short vacuum hose to remove the water from the solution tank.

When the solution tank has been emptied, turn off the vacuums and unplug the power cord.

Place a bucket under the drain valve and open the drain valve to drain the water from the recovery tank.

Close the drain valve and dispose of the water.

Connect Auto-Fill Water Supply

Hose to machine and faucet

Vacuum water out of Solution

Tank

Drain water from Recovery

Tank

30

Image 30
Contents Revised Table of Contents Introduction Power Cords 50’ x 12gauge with male & female plug ends M1200 High Pressure ExtractorPump-out Hose Additional / Optional Equipment AH79DSafety Page SET UP and Operation Electrical Cords2A. Water Supply & Chemical Mixing- Manual Fill 2B. Water Supply & Chemical Dilution Auto-FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Solution Hose Connection of Vacuum HosesHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Troubleshooting Olympus M1200Problem Cause Solution Problem Cause Solution M1200 Solution Flow Path Pump AP48M1200 Wiring Diagram Waste Pump Solution Vacuum #2 Vacuum #1Page Olympus Switch Panel Maintenance Operation IntervalClean Chemical Feed Filter & Foot Valve Clean Vacuum Shutoff Assembly ScreenClean the HYDRO-FILTER Rinse OUT Recovery TankPage Clean Pump Inlet Filter Flush Chemical System Lubricate Pressure Regulator O-RINGS LatchPage Clean Recovery Tank Drain Flange FittingStorage Prep and Freeze Protection Procedures Parts M1200 Pump AP48Pumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty