Olympus M1200 manual Shutdown Procedures

Page 17

Shutdown Procedures:

If using the auto-fill system, turn the water supply off before finishing each job. This will allow use of the water and chemical already in the tank, and will reduce the amount of excess water to be disposed of later.

When finished cleaning, turn off all switches.

If the auto-fill system was used and there is still water in the solution tank, push the float down to release the water inlet hose pressure before disconnecting the hose from the faucet. Disconnect the water inlet hose from the quick-connect on the front of the machine.

Disconnect the solution hose and vacuum hose from the cleaning tool. Pull valve trigger to release pressure from the hose before disconnecting solution hose from cleaning tool.

Disconnect the Hydro-Filter from the vacuum hoses and clean the filter as needed. Replacement filter bags are available (AC11A.)

Disconnect the vacuum hose and solution hose from the machine.

If water remains in the solution tank, use the short vacuum hose and vacuum the excess water from the tank.

If the auto-fill system was utilized, place the chemical feed hose back into the solution tank.

If the waste pump-out system was used:

oTurn the waste pump switch “on” to pump out any remaining water from the recovery tank. o Turn switch off, remove the pump-out hose from the outlet fitting and replace the cap.

o Roll up hose toward drain to remove remaining water from hose.

o Connect ends of hose together to prevent dirty water from dripping from hose during transport.

Disconnect the power cords from the outlets and from the machine.

Remove the float shutoff assembly from the recovery tank and clean filter as needed.

Replace shutoff assembly and tank lid.

Drain any remaining water from the recovery tank and dispose in sanitary drain. Do not use the same bucket to drain the tank that you use to fill the tank.

Roll up all hoses and cords.

Collect and store extractor, all tools, and accessories.

17

Image 17
Contents Revised Table of Contents Introduction Pump-out Hose Power Cords 50’ x 12gauge with male & female plug endsM1200 High Pressure Extractor AH79D Additional / Optional EquipmentSafety Page Electrical Cords SET UP and Operation2B. Water Supply & Chemical Dilution Auto-Fill 2A. Water Supply & Chemical Mixing- Manual FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Vacuum Hoses Connection of Solution HoseHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Olympus M1200 TroubleshootingProblem Cause Solution Problem Cause Solution Pump AP48 M1200 Solution Flow PathWaste Pump Solution Vacuum #2 Vacuum #1 M1200 Wiring DiagramPage Olympus Switch Panel Operation Interval MaintenanceClean Vacuum Shutoff Assembly Screen Clean Chemical Feed Filter & Foot ValveRinse OUT Recovery Tank Clean the HYDRO-FILTERPage Clean Pump Inlet Filter Flush Chemical System Latch Lubricate Pressure Regulator O-RINGSPage Flange Fitting Clean Recovery Tank DrainStorage Prep and Freeze Protection Procedures M1200 Pump AP48 PartsPumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty