Olympus M1200 manual Connection of Solution Hose, Connection of Vacuum Hoses

Page 13

4. Connection of Solution Hose:

Connect the high pressure solution hose to the solution outlet (female quick connect on the front of the machine). Connect the other end of the hose to the male quick connect on the cleaning tool. When you are ready to start cleaning, turn the solution pump switch to the ON position

HP Solution Hose Assembly – AH79D 1/4” id X 25’ with M-F Quick Connects

Connect the male end of the HP Solution Hose Assembly to the female solution outlet fitting on the machine. Connect the female end to the cleaning tool.

5. Connection of Vacuum Hoses:

There are three components used to connect the cleaning tool to the vacuums and recovery tank:

1.A short 4’ vacuum hose: Connected to the vacuum barb on the front of the machine and to the outlet side of the Hydro Filter.

2.A Hydro Filter

3.A 25’ Vacuum Hose: The 2” cuff on the 25’ vacuum hose is connected to the inlet side of the hydro filter. The other end with the 1-1/2” cuff is connected to the cleaning tool.

When ready to begin cleaning, turn both vacuum switches to the ON position. While the M1200 can be operated with only one vacuum for cleaning delicate fabrics, in most situations you will turn both vacuum switches ON.

Short Vacuum Hose

1-1/2” x 4’ with 2” cuffs

Hydro-Filter – AC11

Vacuum Hose

1-1/2” x 25’ with 2” & 1-1/2” cuffs

Optional Accessories

Foam Downer (included):

A key problem with portable extractors is that they have small tanks where foam dissipates slowly. If you have had issues with foam or are anticipating foaming problems, you will want to setup your Foam Downer.

13

Image 13
Contents Revised Table of Contents Introduction M1200 High Pressure Extractor Power Cords 50’ x 12gauge with male & female plug endsPump-out Hose AH79D Additional / Optional EquipmentSafety Page Electrical Cords SET UP and Operation2B. Water Supply & Chemical Dilution Auto-Fill 2A. Water Supply & Chemical Mixing- Manual FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Vacuum Hoses Connection of Solution HoseHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Olympus M1200 TroubleshootingProblem Cause Solution Problem Cause Solution Pump AP48 M1200 Solution Flow PathWaste Pump Solution Vacuum #2 Vacuum #1 M1200 Wiring DiagramPage Olympus Switch Panel Operation Interval MaintenanceClean Vacuum Shutoff Assembly Screen Clean Chemical Feed Filter & Foot ValveRinse OUT Recovery Tank Clean the HYDRO-FILTERPage Clean Pump Inlet Filter Flush Chemical System Latch Lubricate Pressure Regulator O-RINGSPage Flange Fitting Clean Recovery Tank DrainStorage Prep and Freeze Protection Procedures M1200 Pump AP48 PartsPumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty