LUBRICATE PRESSURE REGULATOR O-RINGS:

To maintain consistent adequate pressure delivery to the cleaning tool, the o-rings on the stem of the M1200 pressure regulator must be lubricated regularly.

1.Remove nut from the end of the regulator stem.

2.Remove the black knob from the regulator stem.

3.Remove the spring plate, spring, and spring washer from the regulator stem.

4.Remove the jam nut and washer from the shoulder of the regulator stem retainer. (The set point nuts do not need to be removed.)

Set Point Nuts

Spring

Washer

Stem

 

Spring Plate

 

Spring

 

 

 

 

 

Nut

Jam Nut

Black Knob

Washer

5.Release the latch on the front of the machine and tilt the tanks off of the base assembly. Support the tanks with a chair, bucket, or box while working inside the base.

6.Disconnect the vacuum hose from the vacuum manifold and move it out of the way to gain access to the regulator.

7.Pull the regulator assembly from the base wall opening (back into the base) to access the regulator. A hose may have to be disconnected to move the regulator into a better working position.

8.Hold the body of the regulator with a wrench or vice-grip pliers. Use another wrench to loosen and remove the stem retainer, then remove the stem assembly from the body of the regulator.

LATCH

Loosen & remove Stem Retainer from regulator body

Lubricate Stem O-rings with synthetic grease

9.Use a synthetic grease with Teflon such as Ultra-Slick or Super-Lube to lubricate the o-rings on the regulator stem.

31

Image 31
Contents Revised Table of Contents Introduction M1200 High Pressure Extractor Power Cords 50’ x 12gauge with male & female plug endsPump-out Hose AH79D Additional / Optional EquipmentSafety Page Electrical Cords SET UP and Operation2B. Water Supply & Chemical Dilution Auto-Fill 2A. Water Supply & Chemical Mixing- Manual FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Vacuum Hoses Connection of Solution HoseHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Olympus M1200 TroubleshootingProblem Cause Solution Problem Cause Solution Pump AP48 M1200 Solution Flow PathWaste Pump Solution Vacuum #2 Vacuum #1 M1200 Wiring DiagramPage Olympus Switch Panel Operation Interval MaintenanceClean Vacuum Shutoff Assembly Screen Clean Chemical Feed Filter & Foot ValveRinse OUT Recovery Tank Clean the HYDRO-FILTERPage Clean Pump Inlet Filter Flush Chemical System Latch Lubricate Pressure Regulator O-RINGSPage Flange Fitting Clean Recovery Tank DrainStorage Prep and Freeze Protection Procedures M1200 Pump AP48 PartsPumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty