Olympus M1200 manual Water Supply

Page 11
Adjust the length of the chain connecting the float bottle to the float valve.

Water Supply:

Once the correct metering tip is in place:

oConnect the Auto-Fill Water Supply Hose to the water inlet (the male quick-connect on the front of the machine.)

oConnect the other end of the hose to a water faucet, and then turn on the water.

Hot water can be used as long as the temperature does not exceed 180°F.

Faucet adapter kits (Hydro-Force item #AX21 & AX22) are available that allow connection to different types of faucets if needed.

Chemical

Feed Hose

Connect the Auto-Fill Water Supply Hose to Solution Inlet (Male quick connect on the front of the machine.)

3/8” id X 25’ with F Quick Connect & F Garden Hose Fitting

Connect the Auto-Fill Water Supply Hose to a faucet and turn on the water

To adjust the water level in the solution tank:

Turn off the water supply.

Snap the beaded chain off the connector on the valve.

oMove the bottle down to decrease the water level. o Move the bottle up to increase the water level.

Snap the chain back into the connector.

Turn the water supply back on.

If the chemical is not drawing, or if the tank is not filling or is overflowing, refer to the trouble shooting guide, or contact your distributor for assistance.

Chain

Float Valve

Float Bottle

11

Image 11
Contents Revised Table of Contents Introduction Pump-out Hose Power Cords 50’ x 12gauge with male & female plug endsM1200 High Pressure Extractor AH79D Additional / Optional EquipmentSafety Page Electrical Cords SET UP and Operation2B. Water Supply & Chemical Dilution Auto-Fill 2A. Water Supply & Chemical Mixing- Manual FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Vacuum Hoses Connection of Solution HoseHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Olympus M1200 TroubleshootingProblem Cause Solution Problem Cause Solution Pump AP48 M1200 Solution Flow PathWaste Pump Solution Vacuum #2 Vacuum #1 M1200 Wiring DiagramPage Olympus Switch Panel Operation Interval MaintenanceClean Vacuum Shutoff Assembly Screen Clean Chemical Feed Filter & Foot ValveRinse OUT Recovery Tank Clean the HYDRO-FILTERPage Clean Pump Inlet Filter Flush Chemical System Latch Lubricate Pressure Regulator O-RINGSPage Flange Fitting Clean Recovery Tank DrainStorage Prep and Freeze Protection Procedures M1200 Pump AP48 PartsPumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty