Olympus M1200 manual Problem Cause Solution

Page 20

 

Problem

Cause

Solution

 

Solution Tank

Water source turned off

Turn on faucet or find other water source

 

not filling

Float not on valve arm

Reconnect float to valve arm - Adjust to proper height/level

 

 

Float valve faulty

Repair or replace float valve

 

 

Water hose restricted

Un-kink, clean out or replace hose

 

 

Quick connects faulty

Clean out or replace quick connects

 

 

 

 

 

Solution tank

Float too heavy/ Filled with water

Replace float

 

overflowing

Float & chain tangled

Make sure float chain free & hanging properly

 

 

Float too high

Adjust chain to set float at proper level

 

 

Float valve faulty

Repair or replace float valve

 

 

 

 

*To reduce the risk of fire electrical shock or injury repairs to wiring should only be performed by experienced service technicians.

If you are not experienced in checking electrical wiring contact your nearest authorized service center to perform tests and repairs to wiring and switches.

Contact your distributor for additional troubleshooting assistance, to order parts, or for advice and assistance in performing necessary repairs.

20

Image 20
Contents Revised Table of Contents Introduction Pump-out Hose Power Cords 50’ x 12gauge with male & female plug endsM1200 High Pressure Extractor Additional / Optional Equipment AH79DSafety Page SET UP and Operation Electrical Cords2A. Water Supply & Chemical Mixing- Manual Fill 2B. Water Supply & Chemical Dilution Auto-FillTurquoise Water Supply Priming the High-Pressure Pump Connection of Solution Hose Connection of Vacuum HosesHose Hook Connection of Pump-out Hose Pressure Adjustment Shutdown Procedures Troubleshooting Troubleshooting Olympus M1200Problem Cause Solution Problem Cause Solution M1200 Solution Flow Path Pump AP48M1200 Wiring Diagram Waste Pump Solution Vacuum #2 Vacuum #1Page Olympus Switch Panel Maintenance Operation IntervalClean Chemical Feed Filter & Foot Valve Clean Vacuum Shutoff Assembly ScreenClean the HYDRO-FILTER Rinse OUT Recovery TankPage Clean Pump Inlet Filter Flush Chemical System Lubricate Pressure Regulator O-RINGS LatchPage Clean Recovery Tank Drain Flange FittingStorage Prep and Freeze Protection Procedures Parts M1200 Pump AP48Pumptec #356 Pump AP48 Olympus AUTO-FILL Float Valve Assembly Description Page Page Page Page Page Page Limited Warranty