Monessen Hearth HBDV400N/PSC7, HBDV300N/PV7 manual Rear Wall Vent Installations Flex Vent Pipe

Page 17
Figure 22 -
Top Vent Vertical Sidewall Restrictor

VENT INSTALLATION

HBDV7 Series Direct Vent Gas Fireplace

Finish Wall

 

Vent

 

Termination

Figure 19 -

FP2294

Side View of Final Unit Location

 

Rear Wall Vent Installations - Flex Vent Pipe

Follow Steps 1 and 2 on Page 16.

Step 3

Install the 4” (102 mm) flex vent pipe to the appliance col- lars described in “General Information Assembling Vent Pipes”, Page 13. If the installation requires a 45° angle, grasp the vent pipe close to the appliance collar and bend to 45°. DO NOT exceed 45°. Figure 20

Install the 7” vent pipe in the same manner as Step 2. NOTE: There must be a 1/2” (13 mm) rise in a 12” (305

mm)length of flex vent.

Step 4

Assemble the flex vent to the collars on the termination as you did on the appliance.

Termination

Flex Section

Appliance Collars

FP1473

Figure 20 -

Grasp the vent pipe close to the collar and bend to 45° angle. do not exceed 45°.

Rise

FP1472

Figure 21 -

There must be a 1/2" rise per foot length

Top vent Sidewall Application

NOTE: For all top vent installations where a 90° elbow is the first pipe piece towards a sidewall termination (up and out), an open-center ringed flue restrictor, part #69D3006 must be installed onto the top edge of the firebox flue adapter. To create this open-center restrictor, twist and break off the center rib of the supplied flue restrictor. The installed part should appear similar to that show n in Fig- ure 22.

Since it is very important that the venting system maintain its balance be- tween the combustion air intake and the flue gas

exhaust,

certain

 

limitations

as to

FP2303

vent configurations apply and must be strictly adhered to.

The Vent Graph, showing the relationship between verti- cal and horizontal side wall venting, will help to determine the various dimensions allowable.

Minimum clearance between vent pipes and combus- tible materials is 3" (76 mm) on top, and 1" (25 mm) on the bottom and sides unless otherwise noted.

When vent termination exits through foundations less than 20” (508 mm) below siding outcrop, the vent pipe must flush up with the siding.

It is best to locate the fireplace in such a way that mini- mizes the number of offsets and horizontal vent length.

The horizontal vent run refers to the total length of vent pipe from the flue collar of the fireplace (or the top of the Transition Elbow) to the face of the outer wall.

Horizontal plane means no vertical rise exists on this por- tion of the vent assembly.

54D8000

17

Image 17
Contents HBDV7 Series Direct Vent Gas Fireplace Massachusetts Residents Only Pre-Installation InformationCheck Gas Pressure Signature Command System Owner Important Safety InformationInstaller Never connect unit to private non Please Read the Following CarefullyKnown as wellhead gas Code ApprovalHigh Elevations Product SpecificationsHBDV300 HBDV400 Framing DimensionsFirebox framing PRE-INSTALLATION InformationFireplace Location Cold Climate InsulationMantel Clearances Clearances to combustiblesNever obstruct or modify the air inlet or Outlet grilles louvers. This may create aFinishing Material Secure Fireplace to Floor or FramingOptional TOP Vent Application Optional top vent applicationGeneral Venting Venting Installation InformationInstallation precautions General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances USA InstallationsCanadian Installations Refer to Page 21 for requirements for snorkels How to Use the Vent GraphTwist Lock Pipes 1219 mm Vent InstallationStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Top vent Sidewall Application Rear Wall Vent Installations Flex Vent PipeVent configurations apply and must be strictly adhered to + B = 17 Max Always install horizontal venting on a level plane Venting InstallationVertical Sidewall Installation Twist Lock Pipe Install the 4 flex then 7 flex to the termination Vertical Sidewall installation flex vent pipeDo not back fill around snorkel Below Grade InstallationsVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Roof Flashing Check gas type Install gas piping to fireplace / burner system locationPropane/LP Fireplace InstallationNatural Gas Electrical Wiring Millivolt Check GAS Pressure and Electrical installationDo not use open flame to check for gas LeaksRemote Wall mounted Switch Electrical InstallationRemote Wall Switch Optional DC Remote SystemsNever use an open flame to check for gas leak What to do if YOU Smell GASInitial lighting Operating Instructions Millivolt Approved leak testing methodNever check for gas leak with open FlamePilot position Main burner switchLighting the burner Electrician. Main power must be off when Optional Accessory RequirementsConnecting to main electrical power supply Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower FK-12 Manual Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower On next Command Center Operating Instructions Signature CommandCommand Center FeaturesBattery Installation Function Operation Default Setting Key Combinations for System SettingsSelf Diagnostics Chart Command Center OperationsFUNCTIONS/OPERATION Function OperationGlass Frame Removal Brick installationGlass Removal Do not sprinkle the lava rock or ember Placement of Lava ROCK, Rock Wool and LogsPotential sooting, glass breakage and a fire HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Glass Door Vent SysteMLogs Rock woolStanding Pilot Ignition Symptom Possible Cause ActionTroubleshooting Signature Command System Firebox Components Replacement PartsDescription Qty Firebox componentsStanding Pilot Millivolt Control LP to Natural Gas AccessoriesFuel Conversion Kits Natural Gas to LP Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Description Qty Replacement PartsLogs Description Model Number Vertical Venting7TBLSCTK Horizontal VentingHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededModel EnerGuide Ratings Fireplace Efficiency % Mhsc