GLASS REMOVAL

HBDV7 Series Direct Vent Gas Fireplace

Glass Frame Removal

1.Release two clamps on bottom of fireplace. Figure 59

2.Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace.

3. Set glass frame aside.

Glass Frame

Figure 59 -

Remove Glass Frame

Clamps

FP2588

WARNING

Each clamp has a quick spring force. When

 

 

reinstalling clamps, keep fingers clear.

 

 

brick installation

1.Remove glass door frame and log set.

2.Remove the glass heat shield, baffle and rear bracket.

!WARNING

HOT GLASS WILL

CAUSE BURNS.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN

TO TOUCH GLASS.

3.Install the center firebrick panel on the back wall first. Stand firebrick panel straight up against the back of fireplace with the bottom edge at bottom of inner firebox.

4.Repeat Step 3 with the left and right side firebrick panels. Secure the top of each side firebrick panel to the fireplace with one retainer bracket and one screw.

5.Use a screw gun to drive in the self-drilling screw into the sheet metal through the hole in the retainer bracket.

6.Re-install glass heat shield, baffle and rear bracket.

7.Re-install glass door frame and log set.

54D8000

41

Image 41
Contents HBDV7 Series Direct Vent Gas Fireplace Massachusetts Residents Only Pre-Installation InformationCheck Gas Pressure Signature Command System Owner Important Safety InformationInstaller Never connect unit to private non Please Read the Following CarefullyKnown as wellhead gas Code ApprovalHigh Elevations Product SpecificationsHBDV300 HBDV400 Framing DimensionsFirebox framing PRE-INSTALLATION InformationFireplace Location Cold Climate InsulationMantel Clearances Clearances to combustiblesNever obstruct or modify the air inlet or Outlet grilles louvers. This may create aFinishing Material Secure Fireplace to Floor or FramingOptional TOP Vent Application Optional top vent applicationGeneral Venting Venting Installation InformationInstallation precautions General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances USA InstallationsCanadian Installations Refer to Page 21 for requirements for snorkels How to Use the Vent GraphTwist Lock Pipes 1219 mm Vent InstallationStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Top vent Sidewall Application Rear Wall Vent Installations Flex Vent PipeVent configurations apply and must be strictly adhered to + B = 17 Max Always install horizontal venting on a level plane Venting InstallationVertical Sidewall Installation Twist Lock Pipe Install the 4 flex then 7 flex to the termination Vertical Sidewall installation flex vent pipeDo not back fill around snorkel Below Grade InstallationsVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Roof Flashing Check gas type Install gas piping to fireplace / burner system locationPropane/LP Fireplace InstallationNatural Gas Electrical Wiring Millivolt Check GAS Pressure and Electrical installationDo not use open flame to check for gas LeaksRemote Wall mounted Switch Electrical InstallationRemote Wall Switch Optional DC Remote SystemsNever use an open flame to check for gas leak What to do if YOU Smell GASInitial lighting Operating Instructions Millivolt Approved leak testing methodNever check for gas leak with open FlamePilot position Main burner switchLighting the burner Electrician. Main power must be off when Optional Accessory RequirementsConnecting to main electrical power supply Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower FK-12 Manual Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower On next Command Center Operating Instructions Signature CommandCommand Center FeaturesBattery Installation Function Operation Default Setting Key Combinations for System SettingsSelf Diagnostics Chart Command Center OperationsFUNCTIONS/OPERATION Function OperationGlass Frame Removal Brick installationGlass Removal Do not sprinkle the lava rock or ember Placement of Lava ROCK, Rock Wool and LogsPotential sooting, glass breakage and a fire HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Glass Door Vent SysteMLogs Rock woolStanding Pilot Ignition Symptom Possible Cause ActionTroubleshooting Signature Command System Firebox Components Replacement PartsDescription Qty Firebox componentsStanding Pilot Millivolt Control LP to Natural Gas AccessoriesFuel Conversion Kits Natural Gas to LP Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Description Qty Replacement PartsLogs Description Model Number Vertical Venting7TBLSCTK Horizontal VentingHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededModel EnerGuide Ratings Fireplace Efficiency % Mhsc