Monessen Hearth HBDV300N/PV7, HBDV400N/PV7 Standing Pilot Ignition, Symptom Possible Cause Action

Page 48

HBDV7 Series Direct Vent Gas Fireplace

TROUBLESHOOTING

Standing Pilot Ignition

 

SYMPTOM

POSSIBLE CAUSE

ACTION

 

 

 

 

1.

Spark ignitor will

A. Wire disconnected.

A. Open door and check to make sure wire is connected

 

not light pilot after

 

to ignitor.

 

repeated triggering of

B. Defective ignitor.

B. Check for spark at electrode and pilot. If no spark and

 

piezo.

 

electrode wire is properly connected, replace pilot

 

 

 

assembly.

 

 

C. No gas or low gas pres-

C. Check remote/manual shut off valve from fireplace.

 

 

sure.

Low pressure can be caused by bent lines, restricted

 

 

 

lines, low pressure line pressure. Consult with plumber

 

 

 

or gas supplier.

 

 

D. No Propane/LPG in tank

D. Check Propane/LPG tank. Refill tank.

 

 

 

2. Pilot will not stay lit

A. Defective thermocouple

A. Check that thermocouple flame impinges on thermo-

 

after carefully follow-

 

couple. Clean and/or adjust pilot for maximum flame

 

ing lighting instruc-

 

impingement. Ensure that the thermocouple connec-

 

tions.

 

tion at the gas valve is fully inserted and tight.

 

 

 

Disconnect the thermocouple from the valve, place

 

 

 

one millivolt lead wire on the tip of the thermocouple

 

 

 

and the other meter lead wire on the thermocouple

 

 

 

copper lead. Start the pilot and hold the valve knob in.

 

 

 

If the millivolt reading is less than 15 mV, replace pilot

 

 

 

assembly.

 

 

B. Defective valve

B. If thermocouple is producing more than 15 mV,

 

 

 

replace faulty valve.

 

 

 

 

3.

Pilot burning, valve

A. Defective switch, wall

A. Check switch and wire for proper connection. Place

 

knob turned to “ON”,

switch, remote control or

jumper wires across terminals of switch. If burner

 

switch is turned to

wire

comes on, replace defective switch.If the switch is OK,

 

“ON” or “RS”, but

 

repeat the same procedure on remote control If burner

 

burner will not ignite.

 

comes on, replace remote control.

 

 

 

Place jumper wire across wire at gas valves (terminals

 

 

 

marked TH and TP/TH). If burner comes on, wires are

 

 

 

faulty or connections are bad. Replace wire.

 

 

B. Pilot flame too small

B. If pilot flame is not close enough to the thermopile,

 

 

 

adjust pilot flame.

 

 

C. Defective or malfunction-

C. Check thermopile wire connections to make sure

 

 

ing thermopile

all are tight and that the thermopile is fully inserted

 

 

 

into pilot assembly. Check thermopile with a millivolt

 

 

 

meter. Connect leads to TP and TP/TH terminals on

 

 

 

the control valve. If meter reading is below 325 mV,

 

 

 

replace pilot assembly.

 

 

D. Defective valve

D. Turn valve knob to “On” and switch to “ON.” Take a

reading at the thermopile leads (TP & TP/TH) on the valve. If the meter reads greater than 175 mV and the burner does not light, replace defective valve.

48

54D8000

Image 48
Contents HBDV7 Series Direct Vent Gas Fireplace Pre-Installation Information Check Gas Pressure Signature Command SystemMassachusetts Residents Only Important Safety Information InstallerOwner Please Read the Following Carefully Never connect unit to private nonKnown as wellhead gas Code ApprovalProduct Specifications High ElevationsFraming Dimensions HBDV300 HBDV400PRE-INSTALLATION Information Firebox framingFireplace Location Cold Climate InsulationClearances to combustibles Mantel ClearancesNever obstruct or modify the air inlet or Outlet grilles louvers. This may create aSecure Fireplace to Floor or Framing Finishing MaterialOptional top vent application Optional TOP Vent ApplicationVenting Installation Information Installation precautionsGeneral Venting Canadian Installations1 US Installations2 General Venting Information Termination LocationUSA Installations Canadian InstallationsTermination Clearances How to Use the Vent Graph Twist Lock PipesRefer to Page 21 for requirements for snorkels Vent Installation 1219 mmRear Wall Vent Installation Twist Lock Pipe Rear Wall Vent ApplicationStep Rear Wall Vent Installations Flex Vent Pipe Vent configurations apply and must be strictly adhered toTop vent Sidewall Application + B = 17 Max Venting Installation Vertical Sidewall Installation Twist Lock PipeAlways install horizontal venting on a level plane Vertical Sidewall installation flex vent pipe Install the 4 flex then 7 flex to the terminationBelow Grade Installations Vertical THROUGH-THE-ROOF APPLICA- TionDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Roof Flashing Install gas piping to fireplace / burner system location Check gas typeFireplace Installation Natural GasPropane/LP Millivolt Check GAS Pressure and Electrical installation Electrical WiringDo not use open flame to check for gas LeaksElectrical Installation Remote Wall mounted SwitchRemote Wall Switch Optional DC Remote SystemsWhat to do if YOU Smell GAS Initial lightingNever use an open flame to check for gas leak Approved leak testing method Operating Instructions MillivoltNever check for gas leak with open FlameMain burner switch Lighting the burnerPilot position Optional Accessory Requirements Electrician. Main power must be off whenConnecting to main electrical power supply Or performing service. All wiring shall beJunction BOX Wiring Command Center Wall InstallationWall Switch Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower Optional FAN Blower Systems Blot Automatic Thermostat BlowerFK-12 Manual Blower On next Operating Instructions Signature Command Command CenterFeatures Battery InstallationCommand Center Key Combinations for System Settings Function Operation Default SettingCommand Center Operations Self Diagnostics ChartFUNCTIONS/OPERATION Function OperationBrick installation Glass RemovalGlass Frame Removal Placement of Lava ROCK, Rock Wool and Logs Do not sprinkle the lava rock or emberPotential sooting, glass breakage and a fire HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Vent SysteM Glass DoorLogs Rock woolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Signature Command System Replacement Parts Firebox ComponentsFirebox components Description QtyStanding Pilot Millivolt Control Accessories Fuel Conversion Kits Natural Gas to LPLP to Natural Gas Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Replacement Parts LogsDescription Qty Vertical Venting Description Model NumberHorizontal Venting 7TBLSCTKHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %