HBDV7 Series Direct Vent Gas Fireplace

OPTIONAL FAN BLOWER SYSTEMS

WARNING

Electrical Grounding Instructions: This

appliance is equipped with a three-prong

 

 

(grounding) plug for your protection against

 

shock hazard and should be plugged directly

 

into a properly grounded three-prong

 

receptacle.

 

 

 

 

 

The black and white wires on the AC box

NOTE

wiring harness are marked ‘Blower’, ‘Light’

and ‘Aux’. It is important to use the wires

marked ‘Blower’ or the control will not work

 

correctly.

 

 

WARNING

Electrical connections should only be performed by a qualified licensed electrician. Main power supply must be turned off before connecting the fan to the main electrical power supply or performing service.

BLOTSC SIGNATURE COMMAND BLOWER

To Junction Box

 

In Fireplace

 

 

Optional AC

Optional

Module

Light

{ WHITE

WHITE

BLACK

 

BLACK

BLACK

Optional

{ WHITE

AUX

Blower (300w Max)

GREEN

Connector

 

 

Pin To Control Box

Figure 55 -

 

Blower Wiring Diagram

 

Control Box

The BLOTSC Blower Kit requires the SCSACM A/C Mod-

ule and the TSFSC remote to install and operate this kit.

Refer to blower instructions for installation.

 

FP2103

34

54D8000

Image 34
Contents HBDV7 Series Direct Vent Gas Fireplace Check Gas Pressure Signature Command System Pre-Installation InformationMassachusetts Residents Only Installer Important Safety InformationOwner Known as wellhead gas Please Read the Following CarefullyNever connect unit to private non Code ApprovalProduct Specifications High ElevationsFraming Dimensions HBDV300 HBDV400Fireplace Location PRE-INSTALLATION InformationFirebox framing Cold Climate InsulationNever obstruct or modify the air inlet or Clearances to combustiblesMantel Clearances Outlet grilles louvers. This may create aSecure Fireplace to Floor or Framing Finishing MaterialOptional top vent application Optional TOP Vent ApplicationInstallation precautions Venting Installation InformationGeneral Venting Canadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsTermination Clearances Twist Lock Pipes How to Use the Vent GraphRefer to Page 21 for requirements for snorkels Vent Installation 1219 mmRear Wall Vent Application Rear Wall Vent Installation Twist Lock PipeStep Vent configurations apply and must be strictly adhered to Rear Wall Vent Installations Flex Vent PipeTop vent Sidewall Application + B = 17 Max Vertical Sidewall Installation Twist Lock Pipe Venting InstallationAlways install horizontal venting on a level plane Vertical Sidewall installation flex vent pipe Install the 4 flex then 7 flex to the terminationVertical THROUGH-THE-ROOF APPLICA- Tion Below Grade InstallationsDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Roof Flashing Install gas piping to fireplace / burner system location Check gas typeNatural Gas Fireplace InstallationPropane/LP Do not use open flame to check for gas Millivolt Check GAS Pressure and Electrical installationElectrical Wiring LeaksRemote Wall Switch Electrical InstallationRemote Wall mounted Switch Optional DC Remote SystemsInitial lighting What to do if YOU Smell GASNever use an open flame to check for gas leak Never check for gas leak with open Approved leak testing methodOperating Instructions Millivolt FlameLighting the burner Main burner switchPilot position Connecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beCommand Center Wall Installation Junction BOX WiringWall Switch Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower Blot Automatic Thermostat Blower Optional FAN Blower SystemsFK-12 Manual Blower On next Operating Instructions Signature Command Command CenterBattery Installation FeaturesCommand Center Key Combinations for System Settings Function Operation Default SettingFUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Function OperationGlass Removal Brick installationGlass Frame Removal Potential sooting, glass breakage and a fire Placement of Lava ROCK, Rock Wool and LogsDo not sprinkle the lava rock or ember HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Logs Vent SysteMGlass Door Rock woolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Signature Command System Replacement Parts Firebox ComponentsFirebox components Description QtyStanding Pilot Millivolt Control Fuel Conversion Kits Natural Gas to LP AccessoriesLP to Natural Gas Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Logs Replacement PartsDescription Qty Vertical Venting Description Model NumberHorizontal Venting 7TBLSCTKHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %