REPLACEMENT PARTS

HBDV7 Series Direct Vent Gas Fireplace

HORIZONTAL VENTING

 

Horizontal Vent Termination Kits

Twist Lock Pipe

 

 

 

ve

 

 

scope9 d

 

Components

584F

 

sections twis

V enting

9

djt

 

 

 

Twist Lock Elbows

Shields and Supports

Description

Model Number

Up and Out Side Wall Termination Kit, includes 12” to 16”

7TBLSCTK

Adjustable Termination Pipe, 90° Elbow, Firestops and

 

Cool Touch Termination w/Siding Shield, Additional 12”

 

Section Provided for Min. Vertical Rise. FOR BLDV ONLY

 

Rear Vent Hot Touch Termination Kit w/ 10" to 16"

7TBRHTK

Adjustable Termination Pipe, Firestop, and Hot Touch

 

Termination w/ Siding Shield

 

Up and Out Side Wall Termination Kit w/ 10" to 16"

7TDVSCTK

Adjustable Termination Pipe, 90° Elbow, Firestop, and

 

Cool Touch Termination w/ Siding Shield

 

Rear Vent Cool Touch Termination w/ Siding Shield for

7TRVCT/8

Straight-out Applications and Firestop - 8 pack

 

Rear Vent Hot Touch Termination w/ Siding Shield for

7TRVHT/8

Straight-out Applications and Firestop - 8 pack

 

Termination Guard for 7" T.L. Rear Vent Hot Touch

7TRVTG

Terminations (7TRVT/7TSVKT)

 

Snorkel Termination

7TDVSNORK

7" T.L. DVRTSB Termination Screen Guard

7TBSG

Up and Out Starter Kit w/ 40" Flex Pipe, Firestop, Cool

7FDVSCTK

Touch Termination w/ Siding Shield, and 2 ea. Clamp

 

Bands

 

0" Termination Pipe - 8 pack

7TDVP20/8

10" - 16" Adjustable Termination Pipe - 4 pack

7TDVPA/4

12" - 18" Adjustable Vent Length

7TDVP1218

35" - 64" Adjustable Vent Length

7TDVP3564

8" Vent Pipe - 4 pack

7TDVP8/4

12" Vent Pipe - 4 pack

7TDVP12/4

4" Vent Pipe - 4 pack

7TDVP24/4

36" Vent Pipe

7TDVP36

36" Vent Pipe - 30 pack

7TDVP36/30

48" Vent Pipe

7TDVP48

48" Vent Pipe - 30 pack

7TDVP48/30

45° Elbow for Vertical/Horizontal Offset

7TDV45

45° Elbow for Vertical Offsets - 8 pack

7TDV45/8

90° Elbow for Vertical/Horizontal Offset

7TDV90

90° Elbow for Vertical/Horizontal Offset - 8 pack

7TDV90/8

1" Firestop

7DV1FS

3" Firestop

7DV3FS

1" Attic Insulation Shield

7DV1AIS

Combination Horizontal Offset/Roof Support

7DVCS

 

 

54D8000

59

Image 59
Contents HBDV7 Series Direct Vent Gas Fireplace Massachusetts Residents Only Pre-Installation InformationCheck Gas Pressure Signature Command System Owner Important Safety InformationInstaller Code Approval Please Read the Following CarefullyNever connect unit to private non Known as wellhead gasHigh Elevations Product SpecificationsHBDV300 HBDV400 Framing DimensionsCold Climate Insulation PRE-INSTALLATION InformationFirebox framing Fireplace LocationOutlet grilles louvers. This may create a Clearances to combustiblesMantel Clearances Never obstruct or modify the air inlet orFinishing Material Secure Fireplace to Floor or FramingOptional TOP Vent Application Optional top vent applicationGeneral Venting Venting Installation InformationInstallation precautions General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances USA InstallationsCanadian Installations Refer to Page 21 for requirements for snorkels How to Use the Vent GraphTwist Lock Pipes 1219 mm Vent InstallationStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Top vent Sidewall Application Rear Wall Vent Installations Flex Vent PipeVent configurations apply and must be strictly adhered to + B = 17 Max Always install horizontal venting on a level plane Venting InstallationVertical Sidewall Installation Twist Lock Pipe Install the 4 flex then 7 flex to the termination Vertical Sidewall installation flex vent pipeDo not back fill around snorkel Below Grade InstallationsVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Roof Flashing Check gas type Install gas piping to fireplace / burner system locationPropane/LP Fireplace InstallationNatural Gas Leaks Millivolt Check GAS Pressure and Electrical installationElectrical Wiring Do not use open flame to check for gasOptional DC Remote Systems Electrical InstallationRemote Wall mounted Switch Remote Wall SwitchNever use an open flame to check for gas leak What to do if YOU Smell GASInitial lighting Flame Approved leak testing methodOperating Instructions Millivolt Never check for gas leak with openPilot position Main burner switchLighting the burner Or performing service. All wiring shall be Optional Accessory RequirementsElectrician. Main power must be off when Connecting to main electrical power supplyWall Switch Installation Junction BOX WiringCommand Center Wall Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower FK-12 Manual Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower On next Command Center Operating Instructions Signature CommandCommand Center FeaturesBattery Installation Function Operation Default Setting Key Combinations for System SettingsFunction Operation Command Center OperationsSelf Diagnostics Chart FUNCTIONS/OPERATIONGlass Frame Removal Brick installationGlass Removal Hazard Placement of Lava ROCK, Rock Wool and LogsDo not sprinkle the lava rock or ember Potential sooting, glass breakage and a fireFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Rock wool Vent SysteMGlass Door LogsStanding Pilot Ignition Symptom Possible Cause ActionTroubleshooting Signature Command System Firebox Components Replacement PartsDescription Qty Firebox componentsStanding Pilot Millivolt Control LP to Natural Gas AccessoriesFuel Conversion Kits Natural Gas to LP Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Description Qty Replacement PartsLogs Description Model Number Vertical Venting7TBLSCTK Horizontal VentingHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements If Warranty Service is Needed Lifetime WarrantyFive Year Warranty Basic WarrantyModel EnerGuide Ratings Fireplace Efficiency % Mhsc