Monessen Hearth HBDV400N/PV7, HBDV300N/PV7 manual Features, Battery Installation, Command Center

Page 38

HBDV7 Series Direct Vent Gas FireplaceSIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS

FEATURES

Command Center

Easy Access Function Operation and System Configuration

Operation Confirmation/Fault Diagnostic Indications (LED/ Buzzer)

ON/OFF/HI/Med/Low Operation

Optional Wall Mounting

Control Board

Electronic Ignition

Pilot Lockout safety feature

Electric Power Regeneration from Thermopile to save bat- tery

6-hour Automatic Shut Down Option

Convenient NG/LP Gas Type Conversion

Standing Pilot/Intermittent pilot Conversion

Previous settings Restoration Ability (Memory Off)

Uninterrupted Operation During Power Outage (Automatic Battery Backup)

ON/OFF RF Remote Receiver

Optional Transmitter Learn Capability

RF Receiver

To Thermopile

 

ON/OFF

To Sensor

 

To Sparker

NG/LP

Conversion

 

To Command Center

Control

 

Board

To Stepper Motor

 

To Valve

OFF

LED

ON

Master Switch

Command

Center

AC Module Board (Optional, requires TSFSC Remote)

Battery Door

Easy Snap-on Design

Figure 58 -

Embedded Compact 120 VAC Adapter with Auto Battery

Signature Command System Components

 

Back up Feature

 

Remote Controlled 3-step Blower, Lighting, and On/Off Auxiliary AC Outputs

Transmitter (Optional)

 

 

 

 

 

TSFSC

TSTSC

TSMSC

RTSC

RMSC

Three Flame Height Settings

X

X

X

X

X

Low battery Indication for Transmitter

X

X

X

X

X

Child Proof Lock-out

X

X

X

X

X

LCD Backlight

X

X

X

X

X

Security Codes 16

X

X

X

X

X

Countdown 6 hr Timer

X

X

X

--

--

Standard Thermostatic Control Mode

X

X

--

X

--

Smart Mode Thermostat (Auto Flame & Blower Modulation)

X

X

--

--

--

Three Brightness Settings for Lights

X

--

--

--

--

Three Speed Control for Blower

X

--

--

--

--

On/Off Auxiliary

X

--

--

--

--

Programmable Timer to turn blower on and off

X

--

--

--

--

BATTERY INSTALLATION

The Command Center uses four (4) "AA" batteries as back up for power outages. The system can operate for approxi- mately six (6) months on battery power.

To Install Batteries (not included):

1.Press down the battery door tabs and pull out to remove battery door.

2.Install the batteries as indicated on Command Center.

3.Close battery door by snapping in place.

4.When the four (4) batteries are installed the system will operate without power.

5.The batteries should be replaced when the LED indicates low battery or at least once a year.

38

54D8000

Image 38
Contents HBDV7 Series Direct Vent Gas Fireplace Massachusetts Residents Only Pre-Installation InformationCheck Gas Pressure Signature Command System Owner Important Safety InformationInstaller Known as wellhead gas Please Read the Following CarefullyNever connect unit to private non Code ApprovalProduct Specifications High ElevationsFraming Dimensions HBDV300 HBDV400Fireplace Location PRE-INSTALLATION InformationFirebox framing Cold Climate InsulationNever obstruct or modify the air inlet or Clearances to combustiblesMantel Clearances Outlet grilles louvers. This may create aSecure Fireplace to Floor or Framing Finishing MaterialOptional top vent application Optional TOP Vent ApplicationGeneral Venting Venting Installation InformationInstallation precautions Canadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances USA InstallationsCanadian Installations Refer to Page 21 for requirements for snorkels How to Use the Vent GraphTwist Lock Pipes Vent Installation 1219 mmStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Top vent Sidewall Application Rear Wall Vent Installations Flex Vent PipeVent configurations apply and must be strictly adhered to + B = 17 Max Always install horizontal venting on a level plane Venting InstallationVertical Sidewall Installation Twist Lock Pipe Vertical Sidewall installation flex vent pipe Install the 4 flex then 7 flex to the terminationDo not back fill around snorkel Below Grade InstallationsVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Roof Flashing Install gas piping to fireplace / burner system location Check gas typePropane/LP Fireplace InstallationNatural Gas Do not use open flame to check for gas Millivolt Check GAS Pressure and Electrical installationElectrical Wiring LeaksRemote Wall Switch Electrical InstallationRemote Wall mounted Switch Optional DC Remote SystemsNever use an open flame to check for gas leak What to do if YOU Smell GASInitial lighting Never check for gas leak with open Approved leak testing methodOperating Instructions Millivolt FlamePilot position Main burner switchLighting the burner Connecting to main electrical power supply Optional Accessory RequirementsElectrician. Main power must be off when Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower FK-12 Manual Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower On next Operating Instructions Signature Command Command CenterCommand Center FeaturesBattery Installation Key Combinations for System Settings Function Operation Default SettingFUNCTIONS/OPERATION Command Center OperationsSelf Diagnostics Chart Function OperationGlass Frame Removal Brick installationGlass Removal Potential sooting, glass breakage and a fire Placement of Lava ROCK, Rock Wool and LogsDo not sprinkle the lava rock or ember HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Logs Vent SysteMGlass Door Rock woolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Signature Command System Replacement Parts Firebox ComponentsFirebox components Description QtyStanding Pilot Millivolt Control LP to Natural Gas AccessoriesFuel Conversion Kits Natural Gas to LP Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Description Qty Replacement PartsLogs Vertical Venting Description Model NumberHorizontal Venting 7TBLSCTKHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Basic Warranty Lifetime WarrantyFive Year Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %