Monessen Hearth HBDV400N/PSC7 Below Grade Installations, Vertical THROUGH-THE-ROOF APPLICA- Tion

Page 21

VENTING INSTALLATION

HBDV7 Series Direct Vent Gas Fireplace

Below Grade Installations

When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recom- mended. It allows installation depth down to 7" (178 mm) below grade level. The 7" (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall.

Ensure that sidewall venting clearances are observed. If venting system is installed below ground, we recom- mend a window well with adequate and proper drainage to be installed around the termination area.

If installing a snorkel, a minimum 24" vertical rise is neces- sary. The maximum horizontal run with the 24” vertical pipe

6.Slide the snorkel into the vent pipes and secure to the wall.

7.Level the soil so as to maintain a 4" clearance below snorkel. Figure 33

Do not back fill around snorkel.

A clearance of at least 4” must be maintained between the snorkel and the soil.

If the foundation is recessed, use recess brackets (not supplied) for securing lower portion of the snorkel. Fasten brackets to wall first, then secure to snorkel with self drill- ing #8 x 1/2 sheet metal screws. It will be necessary to extend vent pipes out as far as the protruding wall face. Figure 34

is 36". This measurement is taken from the collar of the fireplace (or transition elbow) to the face of the exterior wall. See the Sidewall Venting Graph for extended horizontal run if the vertical exceeds 24".

1.

Establish vent hole through the wall. Page 19, Figure

 

28

2.

Remove soil to a depth of approximately 16" below base

 

of snorkel. Install drain pipe. Install window well (not

 

supplied). Refill hole with 12" of coarse gravel leaving

 

a clearance of approximately 4" below snorkel. Figure

 

33

3.

Install vent system.

4.

Ensure a watertight seal is made around the vent pipe

 

coming through the wall.

5.

Apply high temperature sealant caulking (supplied)

 

around the 4" and 7" snorkel collars.

Foundation

Recess

Watertight Seal Around Pipe

Snorkel

Wall Screws

Sheet Metal

Screws

FP1966

 

Screws

 

Snorkel

Firestop

 

7”

Minimum 4”

Pipe

Clearance

 

 

Ground

24” (610 mm)

Window

Well

Minimum

 

 

Gravel

 

Drain

 

Foundation Wall

 

Figure 33 -

 

Below Grade Installation

 

BG402a

54D8000

 

Figure 34 -

Snorkel Installation, Recessed Foundation

VERTICAL THROUGH-THE-ROOF APPLICA- TION

his gas fireplace has been approved for:

Vertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. Figure 35

Up to two 45° elbows may be used within the horizontal run. For each 45° elbow used on the horizontal plane, the maximum horizontal length must be reduced by 18” (450 mm).

Example: Maximum horizontal length:

No elbows

= 10’ (3 m)

1 x 45° elbow

= 8.5’ (2.6 m)

2 x 45° elbows = 7’ (2.1 m)

A minimum of an 8’ (2.5 m) vertical rise is required.

Two sets of 45° elbow offsets may be used within the vertical sections. From 0 to a maximum of 8’ (2.5 m) of vent pipe can be used between elbows. Figure 35

21

Image 21
Contents HBDV7 Series Direct Vent Gas Fireplace Pre-Installation Information Check Gas Pressure Signature Command SystemMassachusetts Residents Only Important Safety Information InstallerOwner Never connect unit to private non Please Read the Following CarefullyKnown as wellhead gas Code ApprovalHigh Elevations Product SpecificationsHBDV300 HBDV400 Framing DimensionsFirebox framing PRE-INSTALLATION InformationFireplace Location Cold Climate InsulationMantel Clearances Clearances to combustiblesNever obstruct or modify the air inlet or Outlet grilles louvers. This may create aFinishing Material Secure Fireplace to Floor or FramingOptional TOP Vent Application Optional top vent applicationVenting Installation Information Installation precautionsGeneral Venting General Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsTermination Clearances How to Use the Vent Graph Twist Lock PipesRefer to Page 21 for requirements for snorkels 1219 mm Vent InstallationRear Wall Vent Installation Twist Lock Pipe Rear Wall Vent ApplicationStep Rear Wall Vent Installations Flex Vent Pipe Vent configurations apply and must be strictly adhered toTop vent Sidewall Application + B = 17 Max Venting Installation Vertical Sidewall Installation Twist Lock PipeAlways install horizontal venting on a level plane Install the 4 flex then 7 flex to the termination Vertical Sidewall installation flex vent pipeBelow Grade Installations Vertical THROUGH-THE-ROOF APPLICA- TionDo not back fill around snorkel Vertical THROUGH-THE-ROOF Installation Roof Flashing Check gas type Install gas piping to fireplace / burner system locationFireplace Installation Natural GasPropane/LP Electrical Wiring Millivolt Check GAS Pressure and Electrical installationDo not use open flame to check for gas LeaksRemote Wall mounted Switch Electrical InstallationRemote Wall Switch Optional DC Remote SystemsWhat to do if YOU Smell GAS Initial lightingNever use an open flame to check for gas leak Operating Instructions Millivolt Approved leak testing methodNever check for gas leak with open FlameMain burner switch Lighting the burnerPilot position Electrician. Main power must be off when Optional Accessory RequirementsConnecting to main electrical power supply Or performing service. All wiring shall beJunction BOX Wiring Command Center Wall InstallationWall Switch Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower Optional FAN Blower Systems Blot Automatic Thermostat BlowerFK-12 Manual Blower On next Command Center Operating Instructions Signature CommandFeatures Battery InstallationCommand Center Function Operation Default Setting Key Combinations for System SettingsSelf Diagnostics Chart Command Center OperationsFUNCTIONS/OPERATION Function OperationBrick installation Glass RemovalGlass Frame Removal Do not sprinkle the lava rock or ember Placement of Lava ROCK, Rock Wool and LogsPotential sooting, glass breakage and a fire HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Glass Door Vent SysteMLogs Rock woolStanding Pilot Ignition Symptom Possible Cause ActionTroubleshooting Signature Command System Firebox Components Replacement PartsDescription Qty Firebox componentsStanding Pilot Millivolt Control Accessories Fuel Conversion Kits Natural Gas to LPLP to Natural Gas Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Replacement Parts LogsDescription Qty Description Model Number Vertical Venting7TBLSCTK Horizontal VentingHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Five Year Warranty Lifetime WarrantyBasic Warranty If Warranty Service is NeededModel EnerGuide Ratings Fireplace Efficiency % Mhsc