Kit #HB300CKPS Kit #HB400CKPS
Kit #HB300CKNS Kit #HB400CKNS

HBDV7 Series Direct Vent Gas Fireplace

 

 

REPLACEMENT PARTS

SIGNATURE COMMAND SYSTEM

 

 

 

 

 

 

 

 

Ref.

Description

qty.

HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7

1.

Gas Valve Assy.

1

80D0001

80D0002

80D0001

80D0002

2.

Pilot Assembly

1

80D0006

80D0007

80D0006

80D0007

3.

Control Box

1

80D0018

80D0019

80D0018

80D0019

4.

Command Center

1

80D0005

80D0005

80D0005

80D0005

5.

Burner Tube

1

54D6029

54D6029

54D6004

54D6004

6.

Flexhose with Shutoff Valve

1

69D0030

69D0030

69D0030

69D0030

7.

Injector

1

0H3155

20H3156

62D3004

33D5039

8a,b. Burner Assembly

1

54D5115

54D5115

54D5006

54D5006

9.

Venturi

1

69D1119

69D1026

69D1119

69D1026

10.

Wire Valve Control (not shown)

1

80D0010

80D0010

80D0010

80D0010

11.

Wire Command Ctr Control Box 2'

1

80D0008

80D0008

80D0008

80D0008

 

(not shown)

 

 

 

 

 

12.

A/C Adapter

1

80D0041

80D0041

80D0041

80D0041

 

Accessories

 

 

 

 

 

13.

Hand Held Remote Control w/ HI/LO & Timer

 

 

RMSC

 

14.

Hand Held Remote Control w/HI/LO & Tstat

 

 

RTSC

 

15.

Touch Screen Remote w/Opt. Light, Auxiliary, Blower Control

 

TSFSC

 

16.

Touch Screen Remote Hi/Lo & Timer

 

 

TSMSC

 

17.

Touch Screen Remote Hi/Lo & TStat

 

 

TSTSC

 

18.

SCS Wall Mount Extension Kit (15' wire, rough-in box, wall cover) (not shown)

SCSWEK

 

19.

SCS AC Module (Opt. Blower, Light & Aux. Control)

 

SCSACM

 

*NOTE: TSFSC must be used with SCS A/C Module to control blower, lights and aux.

Fuel Conversion Kits - Signature Command System

Natural Gas to LP

HBDV300

HBDV400

LP to Natural Gas

HBDV300

HBDV400

56

54D8000

Image 56
Contents HBDV7 Series Direct Vent Gas Fireplace Massachusetts Residents Only Pre-Installation InformationCheck Gas Pressure Signature Command System Owner Important Safety InformationInstaller Please Read the Following Carefully Never connect unit to private nonKnown as wellhead gas Code ApprovalProduct Specifications High ElevationsFraming Dimensions HBDV300 HBDV400PRE-INSTALLATION Information Firebox framingFireplace Location Cold Climate InsulationClearances to combustibles Mantel ClearancesNever obstruct or modify the air inlet or Outlet grilles louvers. This may create aSecure Fireplace to Floor or Framing Finishing MaterialOptional top vent application Optional TOP Vent ApplicationGeneral Venting Venting Installation InformationInstallation precautions Canadian Installations1 US Installations2 General Venting Information Termination LocationTermination Clearances USA InstallationsCanadian Installations Refer to Page 21 for requirements for snorkels How to Use the Vent GraphTwist Lock Pipes Vent Installation 1219 mmStep Rear Wall Vent Installation Twist Lock PipeRear Wall Vent Application Top vent Sidewall Application Rear Wall Vent Installations Flex Vent PipeVent configurations apply and must be strictly adhered to + B = 17 Max Always install horizontal venting on a level plane Venting InstallationVertical Sidewall Installation Twist Lock Pipe Vertical Sidewall installation flex vent pipe Install the 4 flex then 7 flex to the terminationDo not back fill around snorkel Below Grade InstallationsVertical THROUGH-THE-ROOF APPLICA- Tion Vertical THROUGH-THE-ROOF Installation Roof Flashing Install gas piping to fireplace / burner system location Check gas typePropane/LP Fireplace InstallationNatural Gas Millivolt Check GAS Pressure and Electrical installation Electrical WiringDo not use open flame to check for gas LeaksElectrical Installation Remote Wall mounted SwitchRemote Wall Switch Optional DC Remote SystemsNever use an open flame to check for gas leak What to do if YOU Smell GASInitial lighting Approved leak testing method Operating Instructions MillivoltNever check for gas leak with open FlamePilot position Main burner switchLighting the burner Optional Accessory Requirements Electrician. Main power must be off whenConnecting to main electrical power supply Or performing service. All wiring shall beWall Switch Installation Junction BOX WiringCommand Center Wall Installation Nected together if a wall switch is not Being used Blotsc Signature Command Blower FK-12 Manual Blower Optional FAN Blower SystemsBlot Automatic Thermostat Blower On next Operating Instructions Signature Command Command CenterCommand Center FeaturesBattery Installation Key Combinations for System Settings Function Operation Default SettingCommand Center Operations Self Diagnostics ChartFUNCTIONS/OPERATION Function OperationGlass Frame Removal Brick installationGlass Removal Placement of Lava ROCK, Rock Wool and Logs Do not sprinkle the lava rock or emberPotential sooting, glass breakage and a fire HazardFinal Installation Left Front Log #6 Installing Universal Andirons Burner, Pilot and Control Compart- ment Vent SysteM Glass DoorLogs Rock woolSymptom Possible Cause Action Standing Pilot IgnitionTroubleshooting Signature Command System Replacement Parts Firebox ComponentsFirebox components Description QtyStanding Pilot Millivolt Control LP to Natural Gas AccessoriesFuel Conversion Kits Natural Gas to LP Signature Command System HBDV300NSC7 HBDV300PSC7 HBDV400NSC7 HBDV400PSC7 Description Qty Replacement PartsLogs Vertical Venting Description Model NumberHorizontal Venting 7TBLSCTKHBDV7 Series Direct Vent Gas Fireplace HBDV7 Series Direct Vent Gas Fireplace Carbon Monoxide Detector Requirements Lifetime Warranty Five Year WarrantyBasic Warranty If Warranty Service is NeededMhsc Model EnerGuide Ratings Fireplace Efficiency %